Owner's manual
Installation and configuration 189
Table 78
Lineside T1 card - XPEC address dip switch settings (Switch S1, positions 3 - 6) (cont’d.)
XPEC
Address
S1 Switch
Position 3
S1 Switch
Position 4
S1 Switch
Position 5
S1 Switch
Position 6
02
Off Off On Off
03
Off Off On On
04
Off On Off Off
05
Off On Off On
06
Off On On Off
07
Off On On On
08
On Off Off Off
09
On Off Off On
10
On Off On Off
11
On Off On On
12
On On Off Off
13
On On Off On
14
On On On Off
15
On On On On
Table 79
Lineside T1 card - T1 Switch 2 (S2) dip switch settings
Dip Switch
Number Characteristic Selection
1
T1 framing On = D4
Off = ESF
2
T1 Coding On = AMI
Off = B8ZS
3–5
CPE or CSU distance See Table 80 "Lineside T1 card -
CPE or CSU distance dip switch
settings (Switch S2, positions 3
- 5)" (page 190)
6
Line processing on T1 link failure On = On-hook
Off = Off-hook
7
Daisy-chaining to MMI On = Yes
Off = No
8
MMI Master or Slave On = Master
Off = Slave
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.