User's Manual
Copyright © 2013 Linear Corporation 187-1132 AX1
BATTERY INSTALLATION & PROGRAMMING PET IMMUNITY TIPS MOUNTING PIR WITHOUT INSTALLATION BRACKETS
MOUNTING PIR WITH INSTALLATION BRACKETS PROGRAMMING WALK TESTING AND OPERATIONAL TESTING
BATTERY REPLACEMENT SPECIFICATIONS LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months. This
warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal
distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from
their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the
part of Linear LLC for consequential damages arising out of or in connection with use or performance
of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of
removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability
and implied warranties for fi tness, are valid only until the warranty expires. This Linear LLC Warranty is in lieu
of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear
Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless
signaling. However, there are some limitations which must be observed.
• For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15
devices. As such, they have limited transmitter power and therefore limited range.
• A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals
that occur on or near their operating frequencies, regardless of code settings.
• Changes or modifi cations to the device may void FCC compliance.
• Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
• A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or
dealer, and these facts should be communicated to the ultimate users.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,NAPPIR01 - P/N:187-1132 AX1 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1 - SIDE 2 OF 2
PET SIZE
JUMPER
15K = 33 LBS.
25K = 55 LBS.
SENSITIVITY
JUMPER
USE LOWEST
SETTING FOR
MAXIMUM
PET WEIGHT
ALWAYS SET
TO LOW FOR
PETS
To take full advantage of the NAPPIR01 pet
immunity features in installations with pets, use
these following steps:
• Mount the PIR with the center of the lens 7-1/2
to 8 feet above fl oor level.
• Set the SENSITIVITY jumper to the LOW
position.
• Set the PET SIZE jumper to the lowest setting
for the maximum pet weight.
• Mount the PIR where pets cannot come within
six feet of the unit by climbing on furniture,
boxes, or other objects.
• Do not aim the PIR at stairs or furniture, boxes,
or other objects that can be climbed by pets.
• NOTE: The NAPPIR01 will provide immunity
to false alarms for an individual animal or a
group of animals whose total weight is equal
to or less than 55 pounds when the room
temperature is above 50° F and below 90° F.
If the optional mounting bracket is used, it
should be mounted with no tilt.
OBSERVE BATTERY POLARITY!!!
PREPARE THE RECEIVER TO
"LEARN" THE TRANSMITTTER
WHEN THE RECEIVER IS READY,
INSTALL THE CR123A 3-VOLT
LITHIUM BATTERY AS SHOWN
PIR WILL SEND A TRANSMISSION
TO THE RECEIVER AND THE
TRANSMITTER'S ID WILL
BE STORED IN THE RECEIVER
CORNER MOUNTING
WITH CORNER
BRACKET
7.5 FEET
ABOVE THE
FLOOR
7.5 FEET
ABOVE THE
FLOOR
WALL MOUNTING
WITH WALL
BRACKET
ATTACH REAR OF
CASE TO THE
PIR BRACKET
- OR -
SECURE PIR
BRACKET WITH
SCREW AND WASHER
7.5 FEET
ABOVE THE
FLOOR
CORNER MOUNT
REAR CASE WITH
FOUR SCREWS
- OR -
WALL MOUNT
REAR CASE
WITH TWO
SCREWS
PRESS WALK TEST
BUTTON ON LEFT
SIDE OF CASE
RED WALK TEST INDICATOR
WILL SHOW THROUGH PIR LENS
UNIT WILL STAY IN
WALK TEST MODE
FOR FIVE MINUTES
WALK ACROSS BEAM PATTERN
WHILE OBSERVING THE
WALK TEST INDICATOR
SNAP CASE
CLOSED BEFORE
WALK TESTING
AFTER WALK TESTING, TEST
THE PIR WITH THE SYSTEM
CONTROL PANEL OR RECEIVER
OUTPUTS: FAULT, RESTORE, LOW BATTERY, STATUS, & TAMPER
TRANSMITTER FREQUENCY: 319.5 MHz
SUPERVISORY INTERVAL: 65 MINUTES
SENSOR TYPE: QUAD ELEMENT
PET IMMUNITY: SELECTABLE: 15 Kg (33 LBS.) OR 25 Kg (55 LBS.)
SENSITIVITY JUMPER: SELECTABLE: HIGH OR LOW
SUGGESTED MOUNTING HEIGHT: 7.5 FT. (2.3 m)
SENSOR RANGE: 30 FT. (9.1 m) X 50 FT. (15.2 m)
MAXIMUM HORIZONTAL SENSING ANGLE: 90°
DIMENSIONS: 3.2” x 2.5” x 1.9” (8.12 x 6.35 x 4.82 cm)
WEIGHT (INCLUDING BATTERY & BRACKET): 3.7 OZ. (104.9 g)
COLOR: WHITE
OPERATING TEMPERATURE: 32° TO 103° F (0° TO 39° C)
RELATIVE HUMIDITY: 5-95% NON-CONDENSING
BATTERY (INCLUDED, NOT INSTALLED): ONE (1) PANASONIC CR123A,
OR EQUIVALENT LITHIUM BATTERY
REGULATORY LISTINGS: FCC PART 15, INDUSTRY CANADA
INCLUDED ACCESSORIES: MOUNTING BRACKETS AND SCREWS, PLASTIC
WALL ANCHORS
THIS DEVICE COMPLIES WITH FCC RULES AND REGULATIONS AS PART 15 DEVICES, AS WELL AS INDUSTRY
CANADA RULES AND REGULATIONS. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS
DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE; (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur
de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
INSTALL CR123A 3-VOLT
LITHIUM BATTERY AS SHOWN
OBSERVE
BATTERY
POLARITY!!!
WHEN THE SYSTEM INDICATES THAT THE
PIR HAS A LOW BATTERY, REMOVE THE
OLD BATTERY AND DISPOSE OF IT PROPERLY
WARNING!
IMPROPER HANDLING OF LITHIUM
BATTERIES MAY RESULT IN HEAT
GENERATION, EXPLOSION OR FIRE
,
WHICH MAY LEAD TO PERSONAL
INJURIES. REPLACE WITH ONLY
TYPE CR123A BATTERY.
WARNING!
BATTERY MUST NOT BE RECHARGED,
DISASSEMBLED, OR DISPOSED OF
IN A FIRE. DISPOSAL OF USED BATTERIES
MUST BE MADE IN ACCORDANCE WITH THE
WASTE RECOVERY AND RECYCLING
REGULATIONS IN YOUR AREA.
WARNING!
KEEP BATTERY AWAY FROM SMALL
CHILDREN. IF BATTERY IS SWAL-
LOWED, PROMPTLY SEE A DOCTOR
CALIFORNIA ONLY: THIS PERCHLORATE WARNING
APPLIES ONLY TO MANGANESE DIOXIDE LITHIUM
CELLS SOLD OR DISTRIBUTED ONLY IN CALIFOR-
NIA, USA. PERCHLORATE MATERIAL: SPECIAL
HANDLING MAY APPLY,
SEE: www.dtsc,ca,gov/hazardouswaste/perchlorate.
For a detail programming guide, the instruction manual should be consulted for
that panel. The below guide should only be used as a reference and not as a
replacement for using the programming instructions.
1. Enter Panel Programming
2. Select Zone #
3. Enter 6 Digit ID number (located on back of unit)
4. Enter Check sum (0-9 ; A-F) (located on back of unit). Digit that follows ¨:¨ on
the Serial ID. For A - F use 0 - 5 (See Below)
5. Enter Point ¨3¨ - for PIR
6. Push On/Off to Save
Alpha Numeric Conversion
A = *0 D = *3
B = *1 E = *4
C = *2 F = *5
NOTE: LET PIR STAND WITH NO INTERFERENCE FOR
FIRST 3 MINUTES.