User's Manual

RSM-WALL
RSM-BASE
Module Installation
Instructions
PRODUCT DESCRIPTION
The Remote Speaker Microphone modules, (RSM-BASE and RSM-WALL),
extend the voice communication range of the PERS-4200 Console. Both of these
units are equipment options designed to enhance the effectiveness of the
PERS-4200 system in an emergency situation.
The function of these modules establish a two-way voice link between a user
and a responding central station. They allow a detailed verbal communication to
the responder. The user can discuss the exact nature of the emergency so that
appropriate assistance can be dispatched.
The RSM-BASE module is plugged into the PERS-4200 Console. It installs
into the PERS via a Linear Expansion Module Interface (LEMI) connector.
Power command/control and two-way voice signals are passed through this
connector. The RSM-BASE (AAE00454) and RSM-WALL (AAE00452) modules
communicate wirelessly.
RSM-WALL modules can be placed in key activity locations in the users home.
One RSM-BASE module can support a maximum of four RSM-WALL modules.
The RSM-WALL modules are either plugged into a standard electrical outlet or
can be wall/ table mounted using a wall transformer with a 5’ retractable power
cord. The RSM-WALL module(s) must be paired with the PERS-4200/ RSM-BASE
module. Pairing instructions are included and must be performed before use.
C
PRODUCT DESCRIPTION RSM-BASE /PERS 4200 INSTALL
Plug RSM-BASE module into Linear Expansion Module
Interface (LEMI) connector on the back of the PERS-4200
console.
BASIC WALL MODULE INSTALL
Plug the RSM-WALL module into the lower outlet of a standard
wall receptacle. The RSM-WALL module and the RSM-BASE
module are now set up for receiving voice communication
through the PERS-4200 Console. The units are ready for
pairing.
WALL TRANSFORMER ACCESS
The RSM-WALL module has a remote transformer that can be
removed from the back of the unit to allow for unit to be wall
mounted or used on a tabletop. Remove the screw fastener
holding the wire access cover.
WALL TRANSFORMER RELEASE
Using a screwdriver, pry spring tab while rocking the transformer
block in the opposite direction. This will allow the transformer to
be released from the RSM-WALL module.
WALL MODULE LOCATIONS
Unravel wall transformer power cord. Mount RSM-WALL
module to a wall using hardware (provided), or, place RSM-
WALL module on a tabletop surface near a wall outlet.
PAIRING RESET/VOLUME CONTROLS
The volume and pairing reset controls are located on the bottom
of the RSM-WALL module. The RSM-WALL module volume is
factory set but may be adjusted if necessary.
PAIRING WALL MODULE TO BASE MODULE
To pair the RSM-WALL module, be sure that PERS 4200
Console is powered up and that the RSM-BASE module is
plugged into the back of console. With a small pen, press and
hold the reset button in for 5 seconds on both modules. The
indicator on the RSM-BASE module will change from steady
red (unpaired) to steady green when the pairing is successful.
UN-PAIRING WALL MODULE/BASE MODULE
If it is necessary to UN-PAIR the RSM-WALL module from the
RSM-BASE module (and PERS_4200 console), do the
following:
On the RSM-WALL module, press and hold reset button for
10 seconds. The indicator fl ashes alternating between red and
green to signify unlearn mode and will return to a steady RED,
completing the un-pair process.
If the RSM-WALL module cannot be un-paired using the above
method, ALL RSM-WALL modules can be un-paired at the
RSM_BASE by pressing and holding the reset button for 30
seconds. During the fi rst 10 seconds the LED will fl ash red and
green. After 30 seconds the indicator will turn RED to indicate
all RSM-WALL modules have been removed from memory.
NOTE: You will have to re-pair those RSM-WALL modules that
are not removed.
An alternative to the above method - Don’t remove, just over
write. The maximum is four. First one unlearned is the fi rst one
overwritten.
LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12)
months. The Warranty Expiration Date is labeled on the product. This warranty extends only
to wholesale customers who buy direct from Linear or through Linear’s normal distribution
channels. Linear does not warrant this product to consumers. Consumers should inquire from
their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations
or liabilities on the part of Linear Corporation for consequential damages arising out of or in
connection with use or performance of this product or other indirect damages with respect to
loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied
warranties, including implied warranties for merchantability and implied warranties for fi tness,
are valid only until Warranty Expiration Date as labeled on the product. This Linear Corporation
Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number
(RPA#). Contact Linear Technical Service at 1-800-421-1587 for an RPA# and other important
details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable
wireless signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations
as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked
by radio signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifi cations to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected
interference or fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
PRINTER’S INSTRUCTIONS:
LINEAR P/N: 232-902 - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1
232902 X1
RSM-BASE
MODULE
RSM-WALL
MODULE
(FRONT VIEW)
RSM-WALL MODULE
(BACK VIEW)
REMOTE
PLUG-IN
TRANSFORMER
5’ POWER
CORD
COVER
FASTENER
WIRE ACCESS
COVER
WALL MOUNTING
HARDWARE
PLUG
OUTLET
FASTENER
RSM-BASE
FASTENER
PERS-4200
CONSOLE
RSM-BASE
MODULE
LEMI
CONNECTOR
RSM-BASE
FASTENER
RSM-WALL
MODULE
PLUG INTO LOWER
OUTLET OF WALL
RECEPTACLE
PAIRING/RESET
BUTTON
VOLUME
CONTROL
(FACTORY SET)
RSM-WALL MODULE
(BOTTOM VIEW)
HELP
Cancel
Home
RSM-BASE
MODULE
RSM-WALL
MODULE
PRESS & HOLD
RESET BUTTON
PERS 4200
CONSOLE
RED/GREEN
FLASHING INDICATOR
REMOVE
WIRE ACCESS
COVER
RSM-WALL MODULE
(BACK VIEW)
PHILLIPS SCREW
PRY SPRING
TAB TO THE LEFT
WHILE MOVING TRANSFORMER
PRONG TO THE RIGHT
WALL TRANSFORMER
RSM-WALL MODULE
(BACK VIEW)
SPRING TAB
SET ON
TABLETOP
WALL MOUNT USING
HARDWARE PROVIDED
EXTEND 5’
POWER CORD
FROM MODULE
AND PLUG
TRANSFORMER
INTO WALL OUTLET

Summary of content (1 pages)