DESCRIPTION
The Delta-3 DT-3+1 is a hand-held four-channel transmitter with a three-channel
section plus an individual one-channel section. It’s designed so that channel 1
may have a system code independent of the other three channels. This transmitter
operating in conjunction with four single-channel receivers, or one multi-channel
receiver, can perform a variety of remote switching tasks. The DT-3+1 has 2
digital encoders (switch A, and switch B). Coding switch “Ais designed for use
with private multiple garage door openers, activated by push buttons 2, 3 and 4.
Coding switch “B” under the back cover is designed for use with less frequently
changed codes, such as a community access gate that can be activated by push
button 1.
NOTE: The transmitter transmits continuously with the button pressed. The red
indicator lights during transmission to indicate battery condition. Should it fail
to illuminate, it is recommended that you replace the 9-volt battery.
STEP 1: Locate coding switch. There are two digital coding switches in the
DT-3+1 transmitter. Code switch “A” is exposed by removing the battery access
cover by inserting your thumbnail or small screwdriver under either of the two
slots at the edge of the case. To access switch “B”, remove the battery and
remove the rear half of the case by gently pulling down and back on the battery
end of the rear case.
(CAUTION: The white plastic push buttons rest freely in the case front and may
fall out if care is not exercised.)
STEP 2: Setting Code Switches. The coding switches have eight keys numbered
1-8. To set coding switch “A”, select any combination of ON or OFF positions for
switch keys numbered 3-8. Use a paper clip or other pointed object (except a
pencil or pen) to set the keys. To set coding switch “B”, select any combination of
ON or OFF positions for switch keys numbered 1-8.
STEP 3A: Code Setting for Four Single-Channel Receivers. Set keys 3-8 of
receivers 2, 3 and 4 to match keys 3-8 of switch “A”. Set keys as follows:
Receiver 1 - Set all eight keys to match switch “B”, activates from button 1
Receiver 2 - Set Key 1 and 2 OFF, match keys 3-8, activates from button 2
Receiver 3 - Set Key 1 ON, Key 2 OFF, match keys 3-8, activates from button 3
Receiver 4 - Set Key 1 OFF, Key 2 ON, match keys 3-8, activates from button 4
STEP 3B: Code Setting for Four-Channel Receiver. Set coding switch keys 3-8 of
the receiver to match keys 3-8 of coding switch “Aof the DT-3+1. Matching these
of the receiver. The receiver keys 1 and 2 do not have to be set. Their functions are
preprogrammed to access channels 1-4. Receiver channels are activated as follows:
Channel 4 of the receiver can
be activated by setting keys
3-8 of coding switch “B” to
match keys 3-8 of coding
switch “A”. Set keys 1 and
2 of coding switch “B to on
position. Channel 4 of receiver
can now be activated by
pressing button 1 of the DT-
3+1.
STEP 4: Test the equipment. Connect the receiver(s) to the operators as described
in the receiver's installation instructions. Be sure the door/gate area is clear.
Activate the transmitter and verify that the receiver triggers the operator. Check
that the correct button on the DT-3+1 activates the desired operator.
WARNING!
BE SURE DOOR
AREA IS CLEAR
OF OBSTRUCTIONS
ACTIVATE TRANSMITTER
TO TEST EQUIPMENT
BATTERY REPLACEMENT
The battery should last 12 to 18 months with normal use. The red LED on the face
of the transmitter will glow when the unit is activated. When the red LED lights
dimly, or not at all when transmitting, the battery needs to be replaced. Remove the
battery access door to change the battery. Any type of 9-volt battery can be used.
REPLACE BATTERY WITH
FRESH 9-VOLT BATTERY
LIMITED WARRANTY
This Nortek Security & Control LLC product is warranted against defects in material and workmanship for twenty-four (24) months. This
warranty extends only to wholesale customers who buy direct from Nortek or through Norteks normal distribution channels. Nortek
Security & Control LLC does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of
the dealer’s warranty, if any. There are no obligations or liabilities on the part of Nortek Security & Control LLC for consequential damages
arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue,
warranties express or implied.
All products returned for warranty service require a Return Authorization Number (RA#). Contact Nortek Security & Control Returns at
1-855-546-3351 for an RA# and other important details.
FCC & IC Notice
This device complies with Part 15 of the FCC Rules and Industry Canada license exempt standard(s). Operation is subject to the
following two conditions:
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference received that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes:
1) (1) l’appareil ne doit pas produire de brouillage, et
2) (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
WARNING:
equipment.
PRINTER’S INSTRUCTIONS:
INSTR,CODE SET,DT-3+1 - P/N: 207408 REV-E - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 11.000” - TOLERANCE +/- .125” SCALE: 1-1

Summary of content (1 pages)