User's Manual

If mounted on a wall, it should be located at a
height greater than the height of any door or window
but still be at least 5.9 inches from the ceiling.
If locating the ADT Carbon Monoxide Alarm in a room
with a fuel burning appliance:
If mounted on the ceiling, it should be at least
12 inches from any wall or light tting.
The alarm should be a horizontal distance of
between 3.28 and 9.84 feet from the potential
carbon monoxide source.
In rooms with sloped ceilings, the alarm should be
located on the high side of the room.
Near paint, thinners, solvent fumes, or air fresheners.
Where dirt or dust could block the detector.
In a bathroom or other areas where it may be exposed
to water splashes, dripping or condensation, e.g.
above an electric kettle.
Where it would be obstructed, e.g. by curtains or
furniture.
In an area where the temperature could be below
-50°F or above 104°F.
Where it could be easily knocked or damaged, or
accidentally turned off or removed.
Over heat sources such as radiators or hot air vents.
Placement Placement