User's Manual
Configuration – Motion Sensor:
Size Value
Parameter 5 1
1 ~ 255 (unsigned decimal) Minutes
(default: 3 minutes)
Parameter 6 1
1 ~ 7
(default: 4)
(Table 1)
(Parameter 5) Re-trigger duration: User can change value from 1 to 255 minutes to setup
the re-trigger time when there is no movement detected in the period of time. Default is 3
minutes.
(Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1 = most
sensitive, 7 = most insensitive, default values= 4
Installation
Notice: If you are installing the entire Z-Wave
TM
system for the first time, please refer to the
installation guide of Z-Wave
TM
Interface Controller before installing M360PIRZ-1.
1. Release cover tab to open the cover and insert two AAA battery into the battery
compartment and close the cover back to sensor.
2. Press the program switch, the LED will flash 5 times which means the sensor has not been
“included” yet or flash once which means the sensor has been “included” already.
3. For “Inclusion (Auto-Inclusion)” in (adding to) a network: To add the M360PIRZ-1 to your
Z-Wave network (inclusion), place your Z-Wave primary controller into inclusion mode and
the distance between sensor and controller is suggested to be in one meter. Press the
Program Switch of M360PIRZ-1 for sending the NIF. After sending NIF, Z-Wave will send
the auto inclusion, otherwise, M360PIRZ-1 will go to sleep after 20 seconds.
4. For “Exclusion” from (removing from) a network: To remove the M360PIRZ-1 from your
Z-Wave network (exclusion), place your Z-Wave primary controller into “exclusion” mode,
and following its instruction to delete the M360PIRZ-1 to your controller. Press the
Program Switch of M360PIRZ-1 once to be excluded.
For “Association”: Press the program switch for sending NIF, the LED will flash once and
send the Wake Up Notification in 5 seconds. Put the Z-Wave
TM
Interface Controller into
“association”, and following its instruction to associate the M360PIRZ-1 with other device.
Support grouping identifier=1. Support one association group (5 nodes). “Association” is
used for other grouping devices chain reaction. Red LED will flash once when trigger.
5. Auto Wake Up:
Use “Wake Up” command to set up the awaking time (from 10 minutes to 1 week) and send
the wake up notification to controller
6. Battery Capacity Detection:
* Use “Battery Get” command to have the battery capacity back in %
* It will detect the battery capacity automatically
* Low Battery Auto Report when power is lower than 2.6V +/- 0.1V
7. Factory Default Reset: Remove cover to trigged tamper switch, LED flash once & send out Alarm
Report. Press Program Switch 10 times within 10 seconds, M360PIRZ-1 will send the “Device Reset
Locally Notification” command and reset to the factory default. (Remark: This is to be used only in the
case of primary controller being inoperable or otherwise unavailable.)
8. All the rest commands depend on Z-Wave standard.
Operation
1. Using adhesive tape to mount M360PIRZ-1 at 2 meters above surface. To enhance
proper operation, place M360PIRZ-1 on the location which can detect the room widely.
2. Walk in front of M360PIRZ-1, sensor will send Basic set On (0xFF) , Red LED willl flash
once and please refer to status report as table below.
- 5 -