User's Manual

3
Alarm V1
Movement &
Tamper Switch
Notifi cation V4
(Movement)
Notifi cation V4
(Tamper Switch)
Alarm Type 0x07
Alarm Level 0x00 (No
movement after
3 min.) 0xFF
(Motion detected)
Notifi cation Type 0x07 0x07
Notifi cation Event 0x08 (Motion
detected)
0x00 (No
movement after
3 min.)
0x03 (Cover
removed)
0x00 (Cover
closed)
Notifi cation Event
Parameter
0x08 (Motion
detected) 0x00
(No movement
after 3 min.)
0x03
CONFIGURATION
The M4IN1Z-1 supports the Confi guration command. Each unit can be
confi gured to operate slightly differently that how it works when it is fi rst
installed.
Using the Confi guration command , the following can be confi gured:
Temperature
The reporting temperature parameters can be set to the consumer’s specifi c
needs, changing from Celsius (default) to FaHrenheit and the reporting
threshold (default 1° C)
Parameter Size Value Default
1
1 bit 0°C 0x00 °C (0x00)
Parameter °F 0x01
2
1 bit 1 - 50 (Setup from
0.1° C - 5° C
1 (1°C)
Humidity
Parameter Size Value Default
3
1 bit 1 - 50 (Setup from
1% - 50%)
10%
Light
Parameter Size Value Default
4
1 bit 0.5 - 50 (Setup
from 0 for OFF or
5% - 50%)
10%
Motion Sensor
Parameter Size Value
5
1 bit 1 - 255 (unsigned
decimal) Minutes
(default: 3 minutes)
Parameter Size Value
6
1 bit 1 - 7
(default: 4)
(Parameter 5) Re-trigger duration: User can change value from 1 to 255
minutes to setup the re-trigger time when there is no movement detected in the
period of time. Default is 3 minutes.
(Parameter 6) Infrared sensor sensitivity adjustment, 7 levels sensitivity, 1=
most sensitive, 7 = most insensitive, default values = 4.
LED Mode
Parameter Size Value
7
1 bit 1 - 3 (Mode 1 - Mode 3)
Mode 1LED Turn Off
(Both Temp / PIR Trigger)
Mode 2 (Breathing
Light Mode) PIR (Quick
Flash)
Mode 3 LED Quick
Flash (Temp / PIR Trigger)
SPECIFICATIONS
Power: 2 - AAA battery (Included)
Signal (Frequency): 908.42 MHz / 916 MHz
Range: Up to 130 feet line of sight
Z-WAVE COMMAND CLASSES
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SENSOR_MULTILEVEL_V7
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
REGULATORY INFORMATION
The M4IN1Z-1is certifi ed to comply with applicable FCC and IC rules and
regulations governing RF and EMI emissions.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including
interference that may cause undesired operation.
FCC Notice
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions may cause
harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
Consult the dealer or an experienced radio/TV technician to help.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment