User's Manual

Using the Bypass Mode
The 2GIG-DW40-345 Wireless Door/Window Contact has a local
bypass feature. This means that the contact allows opening of
a protected door or window without sending a signal to the
control panel.
Figure 8. Push Bypass Button
To operate the bypass feature:
1. With door closed, press and hold the bypass bu on on the
contact un l LED turns on. If the LED is o and the door is
closed, press and hold the local bypass bu on down again
un l the LED turns on.
2. Now open door.
The LED will remain on for up to 30 seconds and indicates that
the door can be opened without sending a signal to the panel.
This local bypass event will be logged on panels with so ware
that supports the Bypass Sensor Log feature. The LED will ash
once every ten (10) seconds to indicate that bypass mode is
ac ve.
3. To deac vate bypass mode, simply close the door. A status
message will be sent to the alarm panel indica ng that the
bypass mode has now been canceled. Note: Status message
will only show on panels with so ware that supports the
Bypass Sensor Log feature.
Disable the Bypass Feature
If the contact is not opened yet, refer to Figure 5 on reverse
side of this page.
1. Pry the ba ery out of sensor base using a at blade screw-
driver. Note loca on of tamper bu on.
Figure 9 . Battery and Tamper Button
2. Insert ba ery + side up, while holding tamper bu on
for three (3) seconds or more to toggle enable/disable
of bypass feature. NOTE: The red LED will ash once to
indicate that the bypass feature is disabled.
3. Release the tamper bu on. This feature will remain
disabled even if the ba ery is replaced
Figure 10. Tamper Button Activation
Re-enable Bypass Feature
Repeat steps 1-3 under Disable the Bypass Feature.
NOTE: The red LED will ash ve (5) times to indicate that
the bypass feature is enabled.
Checking Local Bypass Function Status
1. Remove and re-install ba ery into contact.
2. LED will ash ve (5) mes to indicate local bypass
bu on is enabled or one (1) me if disabled.
Inserting and Replacing Battery
To insert or replace battery:
1. Remove contact base. See Figure 5 on reverse side
2. Remove the ba ery (See Figure 8). Removing the cover
triggers a zone tamper signal, which is transmi ed to the
control panel.
3. Insert the ba ery with the + side up, then snap sensor base
and cover back together.
IMPORTANT: Always dispose and/or recycle used ba eries in accordance with
the hazardous waste recovery and recycling regula ons for your loca on. Your
city, state, or country may also require you to comply with addi onal handling,
recycling, and disposal requirements.
WARNING: Failure to follow these warnings and instruc ons can lead to heat
genera on, rupture, leakage, explosion, re, or other injury, or damage. Do
not insert the ba ery into the compartment in the wrong direc on. Always
replace the ba ery with the same or equivalent type (See Speci ca ons). Never
recharge or disassemble the ba ery. Never place the ba ery in re or water.
Always keep ba eries away from small children. If ba eries are swallowed,
promptly see a doctor.
Specifi cations
Frequency 345 MHz
Battery 3-Volt CR2013 Battery (or Equivalent)
Magnet 5/8” max. gap
Operating Temperature 32°-120°F
Humidity 5-95% RH non-condensing
Compatibility 2GIG receivers
Supervisory Interval Approximately 70 minutes
Wireless Signal Range 275 ft (80m) open air with 2GIG panel
Regulatory Information
WARNING: Changes or modifi cations not expressly approved by Nortek
Security & Control could void the user’s authority to operate the
equipment.
This device complies with FCC Part 15 Rules and Industry Canada
licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may
cause undesired operation of the device.
Cét appareil est conforme la norme d’Industrie Canada exempts de licence
RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1)
cét appareil ne peut pas provoquer d’interférences, et (2) c’et appareil
doit accepter toute interférence, y compris les interférence, y compris
les interférences qui peuvent causer un mauvais fonctionnement de la
dispositif.
FCC ID: WDQ-DW40345 IC: 7794A-DW40-345
Limited Warranty
This Nortek Security & Control LLC product is warranted against defects
in material and workmanship for two (2) years. This warranty extends
only to wholesale customers who buy direct from Nortek Security &
Control LLC or through Nortek Security & Control normal distribution
channels. Nortek Security & Control does not warrant this product to
consumers. Consumers should inquire from their selling dealer as to the
nature of the dealer’s warranty, if any.
There are no obligations or liabilities on the part of Nortek Security &
Control for consequential damages arising out of or in connection with
use or performance of this product or other indirect damages with respect
to loss of property, revenue, or profi t, or cost of removal, installation, or
reinstallation. All implied warranties for functionality, are valid only until
the warranty expires. This Nortek Security & Control Warranty is in lieu
of all other warranties expressed or implied.
2GIG
Nortek Security & Control LLC
1950 Camino Vida Roble, Suite 150
Carlsbad, CA 92008-6517 USA
For technical support in the US and Canada:
855-2GIG-TECH (855-244-4832)
Email: 2gigtechsupport@nortek.com
Visit www.2GIG.com or dealer.2gig.com for technical support hours of operation
For technical support outside of the USA and Canada:
Contact your regional distributor
Visit www.nortekcontrol.com for a list of distributors in your region
Copyright © 2015 Nortek Security & Control LLC10005518X11
BYPASS
BUTTON
(SHADED AREA)
RED LED
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,2GIG-DW40-345 - P/N: 10005518 X11 INK: BLACK - MATERIAL: 16 LB. MEAD BOND - SIZE: 6.000" X 8.000" - TOL. +/- 0.125”- SCALE: 1-1 - FOLDING: 4X TO 1.5” x 2” SIDE 2 OF 2
SCREWDRIVER
BATTERY
CONTACT BASE
TAMPER
BUTTON
RED LED
FLASHES
BACK FINGER PRESSING
TAMPER BUTTON
BACK OF CONTACT
FRONT OF CONTACT
BACK FINGER PRESSING
TAMPER BUTTON