User Manual
CONTROL UNIT DIAGRAM
RESETTING THE ACTUATOR
RESETTING THE CONTROL UNIT
Press and hold hold together for 10 seconds.
Aerwards, control unit will beep.
The chair must be initialized aer a reset.
INITIALIZATION THE CONTROL UNIT
The initialization will run all actuators, to
dene their position. Press and hold the three
buons throughout the initialization, until all
movement has stopped. There will be a total
of six movements, that ends with the backrest
being set in a upright position.
CONNECTION DIAGRAM
There are one power input, two signal input and
seven signal output/channels.
Power Power in
IN1 Chair adjustment membrane panel
IN2 Chair memory membrane panel
WARNING:
If power cable (24V) from Control power unit is inserted in other than Power, the Control unit will
shorting.
Output/channel:
CH1 Seat height front
CH2 Seat height rear
CH3 Footrest
CH4 Backrest
CH5 Seat slide
CH6 Seat depth
IN
POWER
OUT
1 2 1 2 3 4 5 6
NORSAP 4000