Installation Guide

GLASS DOOR MERCHANDISERS
Check to see if contents are blocking
the air duct.
Check the temperature controller for
possible incorrect temperature setting.
Check to see if refrigerant charge is low.
Make sure the door is completely
closed.
NOT INTERIOR LIGHT
Turn off the light switch and turn it on
again.
Make sure the bulb is correctly inserted
into the sockets.
Check the bulb, and replace it if blown.
UNIT NOISY
Make sure to install the unit on level
surface.
Make sure to maintain the minimum
clearance of 6” from the wall.
Check for the loose parts or mounting.
Make sure the tubing is free from any
contact to avoid tubing rattle.
CONDENSATION ON CABINET
AND/OR FLOOR
Reduce the relatively humidity in the
area where the unit is installed.
Gasket on door or head section is not
sealing properly. Repair or replace
gasket as necessary.
4