Use and Care Manual
OPERATIONS
STARTUP
A. The compressor is ready to operate. Plug in the cooler.
B. DIGITAL THERMOSTAT are factory-set to give refrigerators an approxiate
temperature of 35°F, Allow unit to function several hours, completely cooling
cabinet before changing the control setting. Temperature Control Location and
Settings.
• Electronic temperature control is located on front of unit
C. Excessive tampering with the control could lead to service difficulties.
Should it ever become necessary to replace temperature control,
NOTE: If the unit is disconnected or shut off, wait five minutes before starting
again.
RECOMMENDATION : Before loading product we recommend you run your unit
empty for two to three days. This allows you to be sure electrical wiring and
installation are correct and no shipping damage has occurred. Remember, we
does not cover product loss!
MAINTENANCE AND CLEANING
CLEANING THE CONDENSER COIL
Required Tools
• Phillips screwdriver
• Stiff bristle brush
• Adjustable wrench
■ For efficient operation, it is important that the condenser surface be kept
free of dust, dirt, and lint. Condensers accumulate dirt and dust and require
cleaning every 30 days.
■ We recommend cleaning the condenser coil and fins at least once per
month.
■ Clean with a commercial condenser coil cleaner, available from any kitchen
equipment retailer. Brush the condenser fins from top to bottom, not side to
side.
■ After cleaning, straighten any bent condenser fins with a fin comb.