Outdoor Conversion Kit for NRCB (VCK-NRCB) Noritz America Corporation 11160 Grace Avenue, Fountain Valley, CA 92708 Phone 866-766-7489 Fax 714-241-1196 Rev.
Outdoor Conversion Kit for NRCB ・Noritz America does not recommend installing the appliance outdoors if the ambient temperature drops below 23 (-5 ). Additional freeze prevention measures are highly recommended if installed outdoors with conditions below these temperatures. Freeze damage is not covered by Noritz. ℉ ℃ ・The information in this manual is in supplement to the appliance Installation Manual. Outdoor installations following the instructions in this document is permitted.
Outdoor Conversion Kit for NRCB Installation Clearances Page 3
Outdoor Conversion Kit for NRCB Procedure 1. Attach VC-6 (Outdoor Vent Cap) (SET) ■Complete Image Refer to the Installation Procedure of VC-6 (Outdoor Vent Cap) for installation. 2. Remove Front Cover (1) Make sure that power cord of the unit is disconnected. (2) Disconnect Power Do not connect electrical power to the unit until the electrical wiring has been completed. (2) Remove 4 screws w/ washer(M4×12). (1) 3.
Outdoor Conversion Kit for NRCB Procedure (2) Remove Mounting Plate from Circuit Board. Remove 3 screws (M4×12). Circuit Board Mounting Plate - Operation Panel (3) Remove Operation Panel from Mounting Plate. Remove 3 screws (M4×12). (4) Remove Wiring Harness from Operation Panel. Round Head Machine M3X6 S430 Y terminal Round Head Machine M3X6 S430 Terminal Cover Insulation Cover (Do not remove.) Wiring Harness (5) Attach Remote Controller Cord with Y terminals.
Outdoor Conversion Kit for NRCB Procedure 4. Secure Wall Mounting Plate to the wall NOTE Operation Panel cannot be mounted outdoors. Dry Wall Anchors 6X25 Screw - Flat Head Wood 4.1X20 Screw - Flat Head Wood 4.1X20 5. Relocating Operation Panel to a remote location NOTE Operation Panel is not water resistance. Be sure the location for preventing wet. (1) Remove Operation Panel Top Cover. Operation Panel Top Cover (Do not lose it. Order NOs.
Outdoor Conversion Kit for NRCB Procedure (3) Attach Operation Panel to Wall Mounting Plate by Screws - Round Head Machine M3X6. Screw - Round Head Machine M3X6 Operation Panel (4) Attach Operation Panel Top Cover to Operation Panel. Operation Panel Top Cover Operation Panel 6. Plug Operation Panel to the unit Plug the Y terminals to the Terminals on Circuit Board by 2 screws. (There is a Wiring Throughway to pass the cord into the unit on the bottom of the unit.
Outdoor Conversion Kit for NRCB Procedure 7. Attach Gasket to Electrical power cord (1) Pull up Electrical power cord from Wiring Throughway. (2) Wrap Gasket around Electrical power cord, leaving about 3 inch (75mm) from the tied spot. 3" (75mm) Electrical power cord Gasket (3) Pull down Electrical power cord slowly.
Outdoor Conversion Kit for NRCB Procedure 8. Attach NRCB Front Cover for OD Kit (1) Remove Parts List/Technical sheet from the original Front Cover. (View from inside of Front Cover) Parts List/Technical sheet (2) Attach Parts List/Technical sheet to the new NRCB Front Cover for OD Kit. (View from inside of NRCB Front Cover for OD Kit) FADK080 Parts List/Technical sheet 8. Change the dip switch (1) Turn ON dip switch* #3. *The dip switch bank is placed on the circuit board.
Outdoor Conversion Kit for NRCB Procedure (2) Attach NRCB Front Cover for OD Kit to the unit with 4 screws w/ washer(M4×12). 9. Try to operate by using the Operation Panel at the remote location (1) Connect electrical power to the unit. (2) Try to operate by using the Operation Panel at the remote location.