Connecting of Remote Cord to Heater
● Unit has Wire Terminal Block for Remote Cord
Connect the remote cord to the unit's wire terminal block (This wire terminal block has no polarity).
Refer to the unit's installation manual for the location of the unit's wire terminal block and how to install.
(The Unit's installation manual can be downloaded from the Noritz support website.
http://support.noritz.com/)
Two examples of connection to the wire terminal block are shown below.
Do not connect the remote cord to the power supply line.
This product and remote controller will be damaged.
Wire Terminal Block
Wire Terminal Block
Example 1: Wire Terminal Block inside the Unit Example 2: Wire Terminal Block outside the Unit
● Unit does not have Wire Terminal Block for Remote Cord
Connect the remote cord to the unit with ScotchLok (TM) 558 connector (eld supplied), as shown in below illustration.
When using ScotchLok, there is no need to cut the electrical wire inside the unit.
Cut the one side of Y terminal of the remote cord.
*
Use a ScotchLok
(TM)
558 connector with a 18AWG to 22AWG wire gage.
Connect the remote cord to internal wiring.
The internal wiring to remote controller.
NWC-ADAPTER(NAW-1 US) side Unit side
Cut the Y terminal.
Remote Cord