User Guide
4
ImportantSafetyInformation
-
2
(Continued)
Donotplacetheunitortheueterminal
in an indoor environment by means of
adding walls and ceiling (Do not enclose
usingcorrugatedsheets,etc.)
Carbon monoxide poisoning or re may
occur as a result.
(Continued)
Ifthisunitwillbeinstalledinabeauty
salon or other location where hair
sprayoraerosolswillbeused,locate
the unit in a separate area that is
suppliedwithfreshairfromoutdoors.
Prohibited
Be sure the gas/power
supplied matches the
gasontheratingplate.
Installationandservicemustbe
performedbyaqualiedinstaller,
serviceagencyorthegassupplier.
Be sure
to do.
Be sure
to do.
Prohibited
Do not store or use gasoline or other
ammablevaporsandliquidsinthe
vicinityofthisoranyotherappliance.
Prohibited
Donotplaceoruseaspraycan
near
the water heater
ortheueterminal.
Donotallowsmallchildrentoplay
unsupervisedinthebathroom.
Donotallowsmallchildrentobath
unsupervised.
Donotusehairsprayorspray
detergentinthevicinityofthe
heater.
Prohibited
Prohibited
Prohibited
Leavetheproperclearancebetween
thewaterheaterandnearbyobjects
(trees,timber,boxeswithammable
materialsetc.).
Be sure
to do.
*
Indicates suggested clearances for maintenance.
Donotplacecombustiblessuchas
laundry,newspapers,oilsetc.near
the heater
ortheueterminal.
Prohibited
Donotusecombustiblechemicals
suchasoil,gasoline,benzeneetc.in
theneartheheaterortheueterminal.
Prohibited
CarbonMonoxidePoisoningHazard.
Do not install this water heater in a
recreationalvehicleoronaboat.
Prohibited
WARNING
Unit
Left side:
Min. 6" (150mm)
Right side:
Min. 6" (150mm)
Upper:
Min. 36" (900mm)
Front:
Sug. 24" (600mm)
*
Unit
Ex.ForNaturalGas
(NC199OD (GQ-2857WZ US))
[NC199DVC]
Do not place outdoors
Rain may enter the unit
or the burner fire may be
blown by the wind, causing
malfunction or re as a result.
Prohibited
Outdoor
Left side:
Min. 2" (50mm)
Right side:
Min. 2" (50mm)
Front:
Sug. 24" (600mm)
*
Sug. 3" (75mm)
from concentric
pipe*
Upper: Min.
12" (300mm)
[NC199OD]
[NC199DVC]
Flue terminal
Flue terminal
199,900
168,000
2.4
2.4" 2.4"
2.4
192,700
162,200
199,900 BTU
16,000 BTU
202
4.0
1.0 2.4"
10.5"
765
ANSI Z21.10.3-2014/CSA 4.3-2014
15
150
4
NC199OD (GQ-2857WZ US)