Instructions / Assembly
Table Of Contents
!
Notice to Installer
Installation Precautions
t Do NOT install system on line pressure above 90psi.
t Do NOT install system on HOT water line. Failure to limit line
temperature to 100°F may result in housing failure and damage
t Do NOT install the system backwards with the feed water line
connected to the outlet.
t Do NOT use liquid pipe compounds for tting connections.
USE two to three wraps of Teon tape.
®
t Do NOT solder plumbing connections attached to lter housing
or inlet valve. Inlet valve and lter housing will be damaged
by high temperature.
t Do NOT allow system to freeze. Turn o water supply to
housing and drain housing if temperature falls below 32°F.
t Do NOT install system in direct sunlight or where system is
exposed to harsh chemicals or may be subjected to being
struck by moving equipment, carts, mops or any other item
that may cause damage.
t ALLOW a minimum of 3” under the housing to allow for lter
replacement.
t If water hammer is evident, install water hammer arrestors
before the H2Flow™
unit.
t Do NOT overtighten tting connections into inlet valve
or housing outlet.
t Always back-up valves and ttings with a wrench when
installing a
tting to avoid turning the valve.
t Do NOT install the unit behind equipment where it may
be dicult to access the system for lter replacement.
Position the H2Flow™ unit in a suitable location. The direction
of flow through the H2Flow™ unit is always through the inlet first;
keep this in mind when determining installation location. Do NOT
mount the H2Flow™ system near any source of heat. Also, do not
mount the system above any device or area that would be adversely
aected by water.
Installation
-
7. With H2Flow™
ow ball valve at the tap water source. Check for leaks.
inlet valve closed, slowly open the
3
/4" full
8. Open the system inlet feed valve and allow water to ush
through system for 2 minutes at the specied system ow rate
to allow air bubbles to escape. NOTE: NO ACTIVATION IS
REQUIRED FOR THE H2Flow™ SYSTEM TO PERFORM PROPERLY.
FLUSHING IS RECOMMENDED TO ALLOW AIR TO ESCAPE THE
SYSTEM.
9. Make any nal connections. Open all water supply valves and
check for leaks.
10.
If no leaks, turn on equipment and check for normal
operation.
11. Attach the Service Log to the installed H2Flow™ system
and ll in install date.
i
2
t%POPUEJTDBSEUIJTNBOVBMBGUFSJOTUBMMBUJPO5IJTNBOVBM
contains important operation, maintenance and precautionary
information. Please present this manual to user/operator/
owner after installation.
t*UJTTUSPOHMZFODPVSBHFEUIBUZPVSFBEUIJTNBOVBMCFGPSF
installing the system to ensure the best possible installation.
t*OTUBMMBUJPONVTUDPOGPSNUPBMMMPDBMBOETUBUFQMVNCJOHDPEFT
and regulation.
t$POOFDUTZTUFNUPDPMEXBUFSTVQQMZPOMZ8BUFSUFNQFSBUVSF
cannot exceed 100°F/38°C.
t System must be installed in a vertical, upright and level
position.
t)'MPXTZTUFNTNVTUOPUCFVTFEJODPOKVODUJPOXJUI
polyphosphate or any other scale inhibitor.
!
t%POPUVTFXJUIXBUFSUIBUJTNJDSPCJPMPHJDBMMZVOTBGFPSPG
unknown quality without adequate disinfection before or after
the system.
t/PUJDFUPVTFPQFSBUPSPXOFS1MFBTFSFUBJOUIJTNBOVBMGPS
future reference for parts, maintenance, or troubleshooting.
t*UJTSFDPNNFOEFEUIBUBMMQFSTPOOFMSFTQPOTJCMFGPSPQFSBUJPO
and maintenance of this product read the precautions,
operating and maintenance sections of this manual.
1. Turn o all equipment to be fed by the H2Flow™ System,
locate water supply shuto valve and turn OFF.
2. Determine if the water line has an existing water treatment
system. If so, examine system for use of polyphosphate or
other scale inhibitors. H2Flow™ will not be eective if used
in conjunction with other scale inhibitors. Remove the scale
inhibitors from the water line or discontinue installation.
3. Install a
that will feed the water system.
3
/4" full-ow ball valve on the water supply side
4. Anchor the H2Flow™ system on a wall stud or suitable
mounting material spanning wall studs. System must be
vertical and upright.
5. Run a suitable line from the
tap water source to the inlet ball valve on the left side of the
H2Flow™ system. Use 2-3 wraps of Teon
® tape and brace
the inlet ball valve on the system with a wrench when
DPOOFDUJOHUIFGFFEXBUFSMJOF/05&%0/0507&35*()5&/
CONNECTION FITTING INTO BALL VALVE.
3
/4" full-ow ball valve at the
6. Select the appropriate size piping for the equipment being
fed and connect it to the outlet of the H2Flow™.
NOTE: As an option, a drain valve in a tee on the outlet side
of the H2Flow™ could be provided in the line to
facilitate
ushing when changing lters.