Instructions / Assembly

Installation, Operation and
Maintenance Manual
Model H2F
H2Flow™
Anti-Scale System
Chemical-Free, Salt-Free Scale Prevention
Introduction
System Specifications
Maximum Pressure: 90psi/620.1 kPa
Maximum Temperature: 100 °F/38°C
Min.: 35°F/2°C
Inlet/Outlet Connections:
3
/4" FNPT
Service Flow Rate: 0.5 gpm to 10 gpm (1.9 Ipm to 38 Ipm)
Gallon Rating: H2F: up to 6 gpm, 24/7/365 for 2 years
for the H2FC.
Capacity: H2FC cartridge does not have a grain removal
capacity, however, other contaminants present in the water will
gradually degrade the eectiveness of this cartridge. Change the
H2FC cartridge at least once every two years.
PH 6.5 to 8.5
Hardness (maximum) 75 grains (1300 ppm CaCO3)
Temperature 41°F to 100°F (5° to 40°C)
Chlorine < 3 ppm
Iron (maximum) 0.3 mg/l
Manganese (maximum) 0.05 mg/l
Copper (maximum) 1.3 mg/l
Oil & H2S none allowed
Polyphosphate none allowed
Silica (maximum) 10 ppm
The H2Flow™ Anti-Scale System will condition the tap water
providing optimum water characteristics for their specified
applications. The result is reduced equipment maintenance
requirements, longer equipment life and improved quality &
consistency of your products.
The H2Flow™ system is built with the nest and most advanced
materials and each system is quality inspected and pressure
tested prior to shipment. With proper installation and routine
maintenance, you will have years of trouble-free operation.
Please refer to this manual when performing routine lter
changes. The instructions make periodic maintenance quick
and easy and ensure you will receive maximum benet from
your system.
Water Chemistry & Limitations