Use and Care Manual
4
Donotplacetheexhaustventterminal
inanindoorenvironmentbymeansof
adding walls and ceiling (Do not en-
closeusingcorrugatedsheets,etc.)
Carbon monoxide poisoning or re may
occur as a result.
ImportantSafetyInformation
-
2
(Continued)
Ifthisunitwillbeinstalledinalocation
wherehairsprayoraerosolswillbe
used,locatetheunitinaseparate
areathatissuppliedwithfreshair
fromoutdoors.
Prohibited
Besurethegas/power
supplied matches the
gasontheratingplate.
e.g.)EZ111DV(GQ-C3259WX-FFUS)
Installationandservicemustbe
performedbyaqualiedinstaller,
serviceagencyorthegassupplier.
Be sure
to do.
Be sure
to do.
(Continued)
Prohibited
Do not store or use gasoline or other
ammablevaporsandliquidsinthe
vicinityofthisoranyotherappliance.
Prohibited
Donotplaceoruseaspraycan
near
thewaterheaterortheexhaustvent
terminal.
Donotusehairsprayorspray
detergentinthevicinityofthe
heater.
Prohibited
Prohibited
Leavetheproperclearancebetween
thewaterheaterandnearbyobjects
(trees,timber,boxeswithammable
materialsetc.).
Be sure
to do.
*
Indicates suggested clearances for maintenance.
Donotplacecombustiblessuchas
laundry,newspapers,oilsetc.nearthe
heaterortheexhaustventterminal.
Prohibited
Donotusecombustiblechemicals
suchasoil,gasoline,benzeneetc.
intheneartheheaterortheexhaust
ventterminal.
Prohibited
CarbonMonoxidePoisoningHazard.
Do not install this water heater in
arecreationalvehicleoronaboat.
Do not install this water heater
inamobilehomewhenusingSV
conversionkit(“-SV”conguration).
Prohibited
WARNING
Left side:
Min. 3" (75mm)
Right side:
Min. 3" (75mm)
Front:
Sug. 24" (600mm)
*
Sug.3" (75mm)
from vent pipe*
Upper:
Min. 12" (300mm)
Exhaust vent
terminal
Unit
[Indoor Installation]
Left side:
Min. 3” (75mm)
Right side:
Min. 3” (75mm)
[Outdoor Installation]
Front:
Sug. 24" (600mm)
*
Be sure
to do.
[Whensupplyingcombustionair
fromtheindoors]
Checktheairsupplyopening
fordustorobstructions.
Clogged
air supply
opening!!
Made in Japan(Fabriqu
é
au JAPON)
Upper:
Min. 36" (900mm)
Exhaust vent
terminal
Unit