Use and Care Manual
25
The water is cold when only a
single xture is open.
• The unit will not heat the water if the ow rate is less than
0.29GPM (1.1L/min)*.
Open the xture more or open other xtures so that a greater ow
passes through the unit, and the unit should begin heating again.
* Minimum activation ow rate : 0.5 GPM (2.0L/min)
Minimum operating ow rate : 0.29 GPM (1.1L/min)
Amount of Hot Water
The amount of hot water at a
certain xture is not constant.
•
When hot water is demanded at other xtures, the amount available
may be reduced. The maximum ow available from EZ111DV (GQ-C3259
WX-FF US) is 8.7 GPM (33L/min.) at a 45°F (25°C) temperature rise.
The maximum ow available from EZ98DV (GQ-C2859 WX-FF US)
is 7.6 GPM (29L/min.) at a 45°F (25°C) temperature rise.
• Pressure uctuations and other plumbing conditions can
cause the temperature and pressure at a xture to be
unstable, but it should stabilize after a short time.
• There are some types of hot water taps that discharges
large volumes of hot water at rst but stabilize after time.
• To keep the temperature stable, the heater limits the
amount of water that can ow through it to a small amount
initially, but the amount increases over time.
The amount of hot water in the tub
is less/more than the set amount.
• When hot water is used for other xtures while lling the
bath tub, the tub will not ll as much.
• If there is water in the tub already, or when lling is stopped
and restarted, the tub will ll more.
The ow meter alarm does not
sound even when lled to the set
amount.
• The ow meter alarm is set to sound when hot water
is continuously discharged for the set volume of water.
If mixing valves are used, or if cold water is mixed with hot
water at the xture, the tub will ll more than the setting
of the ow meter alarm.
Amount of hot water available
has decreased over time.
Fluctuations in hot water
temperatures.
•
Set water temperature at 115°F to 120°F or 48°C (118°F) to 50°C
(122°F). This will allow you to use a higher ow of hot water thus
meeting the minimum ow requirement of 0.29GPM (1.1L/min)*.
* Minimum activation ow rate : 0.5 GPM (2.0L/min)
Minimum operating ow rate : 0.29 GPM (1.1L/min)
• Clean the water lter of any debris ( p.22)
(Continued)
Setting temperature cannot rise.
• Is the maximum temperature setting appropriate? ( p.17)
• Is the water lter clogged? (
p.22)
•
If the supply water is hard and has not been treated, scale can
build-up in the water heater and decrease the maximum amount of
hot water available. Scale can be removed from the water heater by
ushing the unit periodically. To prevent scale from forming in the
water heater, a water softener or scale inhibitor is recommended.