Instructions / Assembly
Table Of Contents

9
Outdoor Installation
Item Check
• When installing the unit on a balcony, etc., secure an
evacuation route of 24" (600mm) or more in width.
• Provide clearance of 24" (600mm) or more in front of
the unit to facilitate inspection and repair. Do not install
the unit in a location where the unit is out of reach, such
as the wall of the second oor.
• When installing the unit in a common side corridor, provide
a clearance of 47" (1,190mm) or more in front of the unit.
• Set the bottom edge of the exhaust port about
84" (2,130mm) from the corridor oor.
Handrail
common side
corridor
balcony, etc.
Handrail
about 84"
(2,130mm)
• Maintain the following clearance from both combustible
and non-combustible materials.
Surrounding the area of installation
24" (600mm)
or more
47" (1,190mm)
or more
Required Clearances From Heater
Illustration
24" (600mm)
or more
36" (900mm)
or more
3" (75mm) or more