8. Equipment Constant "WBITS10" (VID 23) selects whether Stream 10 primary
message S10F1 sent by the Equipment will have the W-bit set to "0" or "1".
9. Equipment Constant "CONFIGSPOOL" (VID 66) configures whether the
Equipment will transition to "Spool Active" state when a RTY error occurs.
The following table shows the recommended settings for compatibility with various
types of Hosts. Factory (Default) settings are shown in bold.
Table 1-5 Compatibility Settings
Equipment
Constant
E30-93 GEM
3.1
GEM
3.0
GEM
2.0
GEM
1.7
Non-
GEM
CONFIGALARMS
0
22210
CONFIGCONNECT
2
22110
CONFIGEVENTS
1
11110
RPTYPE
False
False False False False False
or True
WBITS5
1
1 or 0 1 or 0 1 or 0 1 or 0 1 or 0
WBITS6
1
11111 or 0
WBITS10
1
1 or 0 1 or 0 1 or 0 1 or 0 0
CONFIGSPOOL
1
00000