User Manual
3-30 Operating Characteristics
3.7.1 S2F41 Commands
The general format for remote commands using the S2F41 message is:
S2F41 [W] * H->E
<L [2]
<A RCMD> * Remote command string
<L
<L [2]
<A CPNAME> * Command Parameter Name
<CPVAL> * Command Parameter Value
>
...
>
> .
The following commands may be sent by the Host to the Equipment:
START
This command starts processing on the Equipment assuming all proper initialization has taken place and
material is present.
S2F41 [W]
<L [2]
<A ‘START’>
<L>
> .
STOP
This command will stop the processing of material at the Equipment. Boards currently in process will be
completed, but no new boards will be loaded.
S2F41 [W]
<L [2]
<A ‘STOP’>
<L>
> .