User Manual
B-4 Appendix B – Collection Events
Table B-1 CEID (continued)
CEID Name Description
Run Time
5001 HeaterMonitorTimeout
The heaters at the dispensing location failed to reach the
specified temperature range within the timeout period.
5002 HeaterMonitorSkipped
The Operator has selected to skip the temperature monitoring
and proceed to dispensing.
5003 HeaterMonitorAborted
The Operator has selected to abort the temperature monitoring
and aborted the run.
5004 PeriodicPurge1
A periodical purging of the needle for Valve 1 has been
performed.
5005
PeriodicFlowrateMeasureme
nt1
A periodical flow rate measurement for Valve 1 has been
performed.
5006 PotLifeWarning1
The pot life of the dispensing material for Valve 1 has reached a
warning level.
5007 PotLifeExpire1 The pot life of the dispensing material for Valve 1 has expired.
5008 AwaitingRecoveryCommand The system has queried the Operator to recover the previous run.
5009 OperatorAckedTerminalMsg The Operator acknowledged a terminal message.
5010 PeriodicPurge2
A periodical purging of the needle for Valve 2 has been
performed.
5011
PeriodicFlowrateMeasureme
nt2
A periodical flow rate measurement for Valve 2 has been
performed.
5012 PotLifeWarning2
The pot life of the dispensing material for Valve 2 has reached a
warning level.
5013 PotLifeExpire2 The pot life of the dispensing material for Valve 2 has expired.
Errors
9000 FMWError
A Fluidmove error has occurred. Use status variable
FMWMostRecentError (1002) to retrieve the error code.
9001 FMWErrorCleared
A Fluidmove error has been acknowledged by the Operator and
the message cleared.