User Manual
Appendix A – Data Dictionary Variables A-11
Table A-1 Data Dictionary Variables (continued)
VID Class Format Name and Description
801
to
817
DV F8
TEMPHTR1CHAN1 – TEMPHTR1CHAN17
. Heater 1 temperatures for
channels 1-17 respectively (DV 801 = channel 1, DV 802 = channel 2,
etc.).
The units are in degrees. No other information is supplied such as the
unit of degrees (°C or °F) or what device the channel is mapped to (i.e.,
pre-dispense station, needle heater, etc.). A value of negative one (-1)
indicates the channel is not monitored or not turned on.
Note: These variables are only updated between boats and only when
monitored by “Verify Temperature Before Initial Dispense”.
818
to
834
DV F8
TEMPHTR2CHAN1 – TEMPHTR2CHAN17. Identical to Data Variables
801-817 except that they refer to Heater 2 channels 1-17, respectively
(DV 818 = channel 1 of Heater 2, DV 819 = channel 2 of Heater 2, etc.).
835
to
851
DV F8
TEMPHTR3CHAN1 – TEMPHTR3CHAN17. Identical to Data Variables
801-817 except that they refer to Heater 3 channels 1-17, respectively
(DV 835 = channel 1 of Heater 3, DV 836 = channel 2 of Heater 3, etc.).
1000 DV A[0-40]
ALARMTEXT
. The Alarm Text (ALTX) for the most recently transitioned
Alarm.
1001 DV Bool
ALARMSEVERITYCODE
. The Severity Code (ALCD low-order 7 bits) for
the most recently transitioned alarm.