User Manual

Machine Variable Definitions 6-7
Table 6-2 Data Variables (continued)
Variable Name ID Storage
Type
Description
NumFailedBoards 107 U4 The number of boards failed since PwrUp or since the
Process State entered the Running state.
PPCHANGENAME 40 A[0..8] The PPID of the Process Program most recently
changed.
PPCHANGESTATUS 41 U1 The last action performed on the Process Program.
1 - Created
2 - Changed
3 - Deleted
ScaleMeasurement1 406 F8 The actual value read from the scale during a Flow Rate
Verification Procedure when Valve 1 is being used.
ScaleMeasurement2 407 F8 The actual value read from the scale during a Flow Rate
Verification Procedure when Valve 2 is being used.
TEMPHTR1CHAN1 –
TEMPHTR1CHAN17
801
to
817
F8 Heater 1 temperatures for channels 1-17 respectively
(DV 801 = channel 1, DV 802 = channel 2, etc.).
The units are in degrees. No other information is
supplied such as the unit of degrees (Centigrade or
Fahrenheit) or what device the channel is mapped to (ie,
pre-dispense station, needle heater, etc.). A value of
negative one (-1) indicates the channel is not monitored
or not turned on.
Note: These variables are only updated between boats
and only when monitored by “Verify Temperature Before
Initial Dispense”.
TEMPHTR2CHAN1 –
TEMPHTR2CHAN17
818
to
834
F8 Identical to Data Variables 801-817 except that they
refer to Heater 2 channels 1-17, respectively (DV 818 =
channel 1 of heater 2, DV 819 = channel 2 of heater 2
etc.)
TEMPHTR3CHAN1 –
TEMPHTR3CHAN17
835
to
851
F8 Identical to Data Variables 801-817 except that they
refer to Heater 3 channels 1-17, respectively (DV 835 =
channel 1 of heater 3, DV 836 = channel 2 of heater 3
etc.)