User Manual

SECS Message Detail 4-61
4.2.101 S10F4 - Terminal Display Single Acknowledge
S10F4 * H<-E
<B [1] ACKC10> . * Acknowledge Code
This Equipment may send the following values for ACKC10:
Table 4-32 S10F4 ACKC10 Values
ACKC10 Description
0x00 Normal.
4.2.102 S10F5 - Terminal Display, Multiblock
S10F5 [W] * H->E, Multiblock
<L [2]
<B [1] TID> * Terminal ID
<L
<A [160] TEXT> * Message Text
...
>
> .
S10F5 can contain multiple TEXT data items. Each TEXT data item is limited to 160 characters. Each
data item in S10F5 will be displayed on a separate line at the Equipment.
The Host sends text to the Equipment. The Equipment interprets TID as follows:
Table 4-33 S10F5 TID Values
TID Description
Any Equipment displays the text on its
CRT.
The Host may optionally set the W-Bit to “1” in S10F5. If so, the Equipment replies with S10F6.