1-10 Introduction
1.6.1 SECS-I Parameters
This section provides hardware settings that apply only to the RS-232 hardware
interface.
NOTE
FmNT currently does NOT support this interface.
Table 1-3 SECS Installation Parameters
Parameter Default Description
Device ID 1 Specified as a value from 0 to 32767 (15 bits).
Baud Rate 9600 Allowable speeds are 110, 150, 300, 600, 1200, 2400, 4800, 9600,
and 19200 Baud.
T1 0.5 Sec Inter-character timeout. Range allowed is 0.1 to 10.0 seconds, at
increments of 0.1 seconds.
T2 10.0 Sec Protocol timeout. Range allowed is 0.2 to 25.0 seconds, at
increments of 0.1 seconds.
T3 45 Sec Transaction Timeout. Range allowed is 1 to 120 seconds, at
increments of 1 second.
T4 45 Sec Inter-Block timeout. Range allowed is 1 to 120 seconds, at
increments of 1.
RTY 3 Transmit failure retry limit. Range allowed is 0 to 31, at
increments of 1.
DUPLIC Off Duplicate Block Detect. May be Enabled (On) or Disabled (Off).
1.6.2 SECS-II Parameters
This section applies only to the Ethernet hardware interface defined in the SECS II
standard.
There are no operator adjustable parameters involved in configuring the SECS II
interface. The operating system of the Equipment computer needs to be made aware
of the network connection.
1.6.3 GEM Configuration
This Equipment is configurable for operation with most older Host Computers which
do not support the GEM message set, or support an older version of GEM.