Manual

9-8 Appendix A
VID Class Format Name and Description
300 SV A[12] FluidFileName1. This is the name of the file containing the
dispensing fluid data for Valve1. The file extension is “.flu”. The
DOS 8.3 file name format is used. There are up to eight
characters reserved for the name and up to three characters for
the extension. The name and extension are thus separated by a
period: “name.ext”. The file name is left justified within the
character string, and spaces pack any remaining space to the
right of the file name.
301 SV A[20] FluidLotNumber1. This is the dispensing fluid lot number
recorded by the operator when the syringe was reloaded. The
format is a twenty character ASCII alphanumeric string containing
the lot number from the fluid syringe. The number is left justified
and blanks fill the remaining space.
302 SV A[14] FluidThawTime1. This is the time stamp in the
YYYYMMDDhhmmss format, at which the fluid was removed from
the refrigerator and began to warm up. Similar to the TIME(39)
variable format.
YYYY = year from 0000 to 9999
MM = month from 01 to 12
DD = day from 01 to 31
hh = hours from 00 to 59
mm = minutes from 00 to 59
ss = seconds from 00 to 59
303 SV A[12] FluidFileName2. This is the name of the file containing the
dispensing fluid data for Valve 2. See FluidFileName1 for a
detailed description.
304 SV A[20] FluidLotNumber2. This is the dispensing fluid lot number for
Valve 2. See FluidLotNumber1 for a detailed description.
305 SV A[14] FluidThawTime2. This is the time stamp for the fluid for Valve 2.
See FluidThawTime1 for a detailed description.
400 DV F8 FlowRate1. The most current fluid flow rate for Valve 1 in
mg./sec.
401 DV F8 FlowRateMin1. The minimum flow rate for Valve 1 in mg./sec.
allowed during this run.
402 DV F8 FlowRateMax1.The maximum flow rate for Valve 1 in mg./sec.
allowed during this run.
403 DV F8 FlowRate2. The most current fluid flow rate for Valve 2 in mg/sec.
404 DV F8 FlowRateMin2. The minimum flow rate for Valve 2 in mg./sec.
allowed during this run.
405 DV F8 FlowRateMax2.The maximum flow rate for Valve 2 in mg./sec.
allowed during this run.
500 DV F4 ConveyorSpeed1. This is the Conveyor 1 belt speed in in./sec.
when it is moving a board to the next dispensing position.