Manual
9-6 Appendix A
VID Class Format Name and Description
51 SV U4 SPOOLLOADSUBSTATE. The current state within the SPOOL
LOAD super-state.
6 = Spool Not Full
7 = Spool Full
52 SV A[16] SPOOLSTARTTIME. The date and time at which the first
message was written to the current spool file. Format is:
YYYYMMDDhhmmsscc.
See description of CLOCK variable above for format details.
53 SV U4 SPOOLSTATE. The current spool state within the POWER ON
super-state.
1 = Spool Active
2 = Spool Inactive
54 SV U4 SPOOLUNLOADSUBSTATE. The current spool state within the
SPOOL UNLOAD super-state.
3 = Purge Spool
4 = Transmit Spool
5 = No Spool Output
61 EC BOOL Internal to the Equipment. The Host should not access this
variable.
62 EC BOOL OVERWRITESPOOL. This EC determines the action to be taken
by the Equipment when the Spool file reaches its capacity.
TRUE = Overwrite Spool
FALSE = Do Not Overwrite Spool
63 EC U4
CONFIGSPOOL. This EC determines whether spooling is
enabled or disabled for this Equipment.
0 = Disabled
1 = Enabled
67 DV U4 ECIDCHANGE. The VID of the Equipment Constant most
recently changed by the Operator.
71 EC U1 TIMEFORMAT. Determines whether STIME is sent in 12-byte or
16-byte format.
0 = 12-byte data format
1 = 16-byte data format
101 SV A[20]
SoftwareID. The FmNT SW name and version code. The software
name format is: “FmNT M.mm
A - 7ltrSuf”. The version is in Major
and minor format with a period separating the parts. Up to seven
letters in an alphanumeric suffix follow the capitol A and hyphen
in the name as shown. Spaces pack any remaining space to the
right of the software ID.