Manual

Machine Variable Definitions 6-7
Variable Name ID Storage
Type
Description
OFFLINESUBSTATE 42 U1 This variable determines the Control State that the
Equipment enters when it enters the OffLine super-
state. The allowable values are: 1 - Equipment
Offline, 2 - Attempt Online, 3 - Host Offline.
ONLINEFAILED 43 U1 This variable controls the entry state resulting from
a failed attempt to go Online. The two values are: 1
- Equipment Offline, 3 - Host Offline.
ONLINESUBSTATE 44 U1 This variable controls the entry state resulting from
a successful attempt to go Online. The two values
are: 4 - Online - Local, 5 - Online - Remote.
OVERWRITESPOOL 62 BOOL This variable enables overwriting the Spool when it
becomes full.
PurgeEnabled 600 BOOL The state of periodic purging operations. 1 -
Enabled, 0 - Disabled
RPTYPE 17 BOOL This variable enables the Equipment to send
annotated reports to the Host on request.
TempNeedleTarget 206 U2 The needle temperature set point.
TempTooCool 202 List The low temperature limit for acceptable control.
The format for the list is found in Appendix A.
TempTooHot 201 List The high temperature limit for acceptable control.
The format for the list is found in Appendix A.
TempZoneSetpoints 200 List The desired temperatures for each heater zone in
deg. C. The format for the list is found in Appendix
A.
VisionFailures 112 U4 The number of vision system failures counted by
the FmNT SW since the Power On event or latest
Process Program change. The Host may clear this
variable to measure failures during a run.
WBITS10 18 U1 This variable determines the default state of the W
bit for all messages in stream 10 sent from the
Equipment to the Host.
WBITS5 19 U1 This variable determines the default state of the W
bit for all messages in stream 5 sent from the
Equipment to the Host.
WBITS6 20 U1 This variable determines the default state of the W
bit for all messages in stream 6 sent from the