SECS Scenarios 5-11
5.3.4 Alarm Report (GEM, Ver 3.1 Compatibility)
NOTE
This scenario is provided only for compatibility with Host computers
which support GEM, Ver 3.1.
Table 5-24 SECS Messages Alarm Report (GEM, Ver 3.1 Compatibility)
Step SECS Message Description
1. The Equipment Constant ConfigAlarms is set to 2 for non-GEM
compatibility.
The Equipment recognizes that an alarm condition has gone
"on" (i.e. has become Unsafe).
2. H <- E S5F73 [W] The Equipment reports the Alarm going on. The high-order bit
of ALCD is "1".
3. H -> E S5F74 If the W-bit of S5F74 is 1, the Host acknowledges the Alarm.
4. The Equipment recognizes that the alarm condition has gone
"off" (i.e. has become Safe).
5. H <- E S5F73 [W] The Equipment reports the Alarm going off. The high-order bit
of ALCD is "0".
6. H -> E S5F74 If the W-bit in S5F74 is 1, the host acknowledges the Alarm.
5.3.5 Alarm Report (GEM, Ver 1.7 Compatibility)
NOTE
This scenario is provided only for compatibility with Host computers
which support GEM, Ver 1.7.
Table 5-25 SECS Messages Alarm Report (GEM, Ver 1.7 Compatibility)
Step SECS Message Description
1. The Equipment Constant ConfigAlarms is set to 1 for GEM, Ver
1.7 compatibility.
The Equipment recognizes that an alarm condition has gone
"on" (i.e. has become Unsafe).
2. H <- E S5F71 [W] The Equipment reports the Alarm going on. The high-order bit
of ALCD is "1".
3. H -> E S5F72 If the W-bit in S5F71 is 1, the Host acknowledges the Alarm.
4. The Equipment recognizes that the alarm condition has gone
"off" (i.e. has become Safe).
5. H <- E S5F71 [W] The Equipment reports the Alarm going off. The high-order bit
of ALCD is "0".
6. H -> E S5F72 If the W-bit in S5F71 is 1, the Host acknowledges the Alarm.