SECS Message Detail 4-49
4.67 S6F9 - Event Report
S6F9 [W] * H<-E, Multiblock
<L [4]
<B [1] 00> * PFCD
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 DSID> * DSID=RPTID Report ID
<L
<V> * Variable Value
...
>
>
...
>
> .
NOTE
This message is provided only for compatibility with older Host
computers which do not support GEM. (See section 2.7.2, "Gem
Configuration".)
If the Equipment Constant "ConfigEvents" is set to "0", the Equipment sends S6F9
instead of the normal S6F11 Event Report.
A Collection Event has occurred at the Equipment. The Host has enabled event
reporting for this CEID (see S2F37). The Host has set the Equipment Constant
RpType to "False" (normal report format desired). The Equipment sends one or
more Event Reports which the Host has previously linked to that CEID (see S2F35).
Each report contains specific Variables which the Host has previously defined for
that Report (see S2F33).
PCFD is always zero.
The Equipment generates a value for DATAID to uniquely identify this
Conversation. If S6F9 is multiblock, the Equipment first sends the S6F5/S6F6
Inquire/Grant transaction, and the DATAID in S6F9 will match DATAID in S6F5.