Manual
SECS Message Detail 4-43
4.57 S5F71 - Alarm Report Block Send
S5F71 [W] * H<-E
<L [2]
<U1 0> * ALPY Alarm Priority
<L [1]
<L [4]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On
F = Alarm Off
<U4 ASER> * ASER Alarm Serial Number
<A [16] 'YYYYMMDDhhmmsscc'> * CLOCK
>
>
>.
NOTE
This message is provided only for compatibility with Host
computers which support an older version of GEM.
If the Equipment Constant "ConfigAlarms" is set to "1", the Equipment sends S5F71
instead of the normal S5F1 Alarm Notification Send.
The GES-1993 reports that an alarm condition has changed.
ALID identifies the Alarm.
ASTAT value is "True" (Non-zero) if this alarm is currently On (Unsafe), or "False"
(Zero) if it is currently Off (Safe).
ASER (Alarm Serial Number) is assigned by the Equipment. Its value begins at "1"
and is incremented by 1 for each alarm reported.
ALPY (Alarm Priority) is always zero.
CLOCK indicates the date and time of the alarm change.
Equipment Constant "Wbits5" controls whether the Equipment sends S5F71 with w-
bit= "1" (Reply Expected) or "0" (No Reply Expected).