Manual

SECS Message Detail 4-41
4.54 S5F6 - List Alarm Data
S5F6 * H<-E, Multiblock
<L
<L [3]
<B [1] ALCD> * ALCD - Alarm On/Off and
Severity Code
<U4 ALID> * Alarm ID
<A ALTX> * ALTX - Alarm Text
>
...
>.
The high-order bit of ALCD will be "1" if this alarm is currently On (Unsafe), or "0"
if it is currently Off (Safe). The low-order seven bits of ALCD contain the severity
code for this alarm.
For any invalid ALID specified in S5F5, the corresponding entry in S5F6 has the
following special error format:
<L [3]
<B> * ALCD - alarm On/Off and Severity
Code
<U4 ALID> * Alarm ID
<A> * ALTX - Alarm Text
>
If S5F5 specified all alarms, S5F6 reports alarms in order by alarm ID.
4.55 S5F7 - List Enabled Alarms Request
S5F7 W . * H->E
The Host requests the Equipment to send the current status of all Alarm IDs which
are currently enabled (See S5F3).