Manual
SECS Message Detail 4-37
4.48 S2F48 - Variable Limit Attributes Send
S2F48 * H <- E
<L
<L [2]
<U4 VID> * Variable ID
<L [4]
<A UNITS> * Units of Measure
<LIMITMIN> * Minimum Limit
<LIMITMAX> * Maximum Limit
<L * Up to 7 Possible
<L [3]
<B [1] LIMITID> * Limit ID
<UPPERDB> * Upper Deadband
<LOWERDB> * Lower Deadband
>
...
>
>
>
...
>.
The Equipment sends this message in response to a Host S2F47 and reports the
characteristics of limits for specified variables. In response to a request from the
Host for all limits for all variables, only variables with limits defined are reported. If
the Host requests specific variables which are not eligible for limits monitoring, the
following message will be reported for that variable:
S2F48 * H <- E
<L
<L [2]
<U4 VID> * Variable ID
<L> * Not eligible for
Limits
>
...
>.