Manual

SECS Message Detail 4-21
The Host can delete all report definitions and associated links in the Equipment by
using the following special format:
S2F33 W * H->E
<L [2]
<U4 DATAID> * DATAID
<L>
>.
4.34 S2F34 - Define Report Acknowledge
S2F34 * H<-E
<B [1] DRACK> . * DRACK - Acknowledge Code
Normally, DRACK is zero. Any non-zero DRACK indicates the Equipment has
rejected the entire S2F33 message.
Table 4-6 DRACK Values
DRACK Description
0x00 OK
0x02 Denied. Invalid format.
0x03 Denied. At least one RPTID already defined.
0x04 Denied. At least one VID does not exist.