Manual

SECS Message Detail 4-19
4.31 S2F31 - Date and Time Send
S2F31 W * H->E
* TIME - Date and Time
<A 'YYMMDDhhmmss'> . * If TIMEFORMAT = 0
-OR-
<A 'YYYYMMDDhhmmsscc'> . * If TIMEFORMAT = 1
The Host commands the Equipment to set its Date and Time base to the specified
value.
When the Equipment receives a good S2F31, it sets its internal clock/calendar.
When receiving S2F31, the Equipment will discard an invalid date or time. For
example, if the date is good but the time is bad, the Equipment sets its date but not its
time.
4.32 S2F32 - Date and Time Acknowledge
S2F32 * H<-E
<B [1] TIACK> . * TIACK - Acknowledge Code
Table 4-5 TIACK
TIACK Description
0x00 Normal. Everything correct.
0x01 Invalid Date and/or Time.