Manual

4-12 SECS Message Detail
4.19 S2F15 - New Equipment Constant Send
S2F15 W * H->E
<L
<L [2]
<U4 VID> * Equipment Constant ID
<V>
>
...
>.
The Host sends new values for desired Equipment Constants. Several Equipment
Constants can be specified if desired.
Only VIDs of class EC can be used in this message.
4.20 S2F16 - Equipment Constant Send Acknowledge
S2F16 * H<-E
<B [1] EAC> . * Equipment Acknowledge Code
Normal completion returns a zero (0) in EAC. If any ECID or ECV in S2F15 is
invalid, then EAC contains a non-zero value, and the Equipment rejects the entire
S2F15.
Table 4-2 EAC Values
EAC Description
0x00 OK
0x01 At least one ECID invalid
0x03 At least one ECV out of range