Appendix F - Variables Grouped by Fluidmove Activity F-151
Status Variables
The following status variables indicate what units the LMO offsets are stored in (“psi” or “kPa”). These variables are for internal use and cannot be
modified.
Table F.64-2 Electronic Pressure LMO – Status Variables
Status Variable Name ID SECS Type Description
sv_PressLmoOffsetUserUnit_V1 1830 A[10] Units that E/P LMO offsets are stored in for Valve 1: “kPa” or “psi”
sv_PressLmoOffsetUserUnit_V2 1831 A[10] Units that E/P LMO offsets are stored in for valve 2: “kPa” or “psi”
When an E/P LMO offset is changed by the operator via the user interface, a collection event will occur and the associated data variables will contain the
old and new values.
Collection Events
Table F.64-3 Electronic Pressure LMO – Collection Events
Collection Event Name CEID
Related Data
Variables
Description
ce_PressureOffsetChanged 8033
450
575
574
Collection event when operator changes an E/P LMO offset value.
ce_PressureOffsetUnitsChanged 8034
450
453
451
Collection event when the internal units of E/P LMO offset changes.
This value will change when “Air Pressure” units are changed from the
main configuration dialog and after the LMO offset dialog is visited and
exited.