Appendix F - Variables Grouped by Fluidmove Activity F-147
c_OverflowAccumulatedTotalMG_S1/S2
Contains the current accumulated weight of scale in milligrams.
This is NOT the total weight in the cup. Total weight in the cup is the total of this variable (accumulated weight) plus pre-tared weight.
It is recommended that the SECS/GEM host does not change this variable and if changed will indirectly affect the total weight.
If this value is changed, c_OverflowCurrentCupWeightMG_S1/S2 will also be changed to the new value plus the existing pre-tare value.
c_OverflowPreTareMG_S1/S2
Contains the current “pre-tare” weight in milligrams.
This is NOT the total weight in the cup. Total weight in the cup is the total of accumulated weight plus this value (pre-tared weight).
It is recommended that the SECS/GEM host does not change this variable and if changed will indirectly affect the total weight.
If this value is changed, c_OverflowCurrentCupWeightMG_S1/S2 will also be changed to the new value plus the existing accumulated value.
c_OverflowLastWeightReadingStable_S1/S2
Indicates if the last weight reading returned from the scale was “stable”
This equipment constant is for internal use and it is recommended that the SECS/GEM host does not change this value
In general, c_OverflowCurrentCupWeightMG_S1/S2 (total weight) = c_OverflowAccumulatedTotalMG_S1/S2 (accumulated weight) +
c_OverflowPreTareMG_S1/S2 (pre-tare weight).
Table F.63-1 Scale Overflow Equipment Constants
Variable Name ECID
SECS
Type
Storage
Type
FmConfig.ini Entry
[Scale Manager]
c_OverflowProtectionEnabled_S1 6703 A[4] ASCII
Overflow Protection Enabled =
c_OverflowProtectionEnabled_S2 6704 A[4]
ASCII
Scale 2 Overflow Protection Enabled =
c_OverflowMaxCapacityMG_S1 6705 A[30] FLT
Max Capacity (mg) =
c_OverflowMaxCapacityMG_S2 6706 A[30]
FLT
Scale 2 Max Capacity (mg) =
c_OverflowWarningPercentage_S1 6707 A[30] FLT
Warning Percentage =