Owner's manual
Appendix F - Variables Grouped by Fluidmove Activity F-147
c_OverflowAccumulatedTotalMG_S1/S2
• Contains the current accumulated weight of scale in milligrams.
• This is NOT the total weight in the cup. Total weight in the cup is the total of this variable (accumulated weight) plus pre-tared weight.
• It is recommended that the SECS/GEM host does not change this variable and if changed will indirectly affect the total weight.
• If this value is changed, c_OverflowCurrentCupWeightMG_S1/S2 will also be changed to the new value plus the existing pre-tare value.
c_OverflowPreTareMG_S1/S2
• Contains the current “pre-tare” weight in milligrams.
• This is NOT the total weight in the cup. Total weight in the cup is the total of accumulated weight plus this value (pre-tared weight).
• It is recommended that the SECS/GEM host does not change this variable and if changed will indirectly affect the total weight.
• If this value is changed, c_OverflowCurrentCupWeightMG_S1/S2 will also be changed to the new value plus the existing accumulated value.
c_OverflowLastWeightReadingStable_S1/S2
• Indicates if the last weight reading returned from the scale was “stable”
• This equipment constant is for internal use and it is recommended that the SECS/GEM host does not change this value
In general, c_OverflowCurrentCupWeightMG_S1/S2 (total weight) = c_OverflowAccumulatedTotalMG_S1/S2 (accumulated weight) +
c_OverflowPreTareMG_S1/S2 (pre-tare weight).
Table F.63-1 Scale Overflow – Equipment Constants
Variable Name ECID
SECS
Type
Storage
Type
FmConfig.ini Entry
[Scale Manager]
c_OverflowProtectionEnabled_S1 6703 A[4] ASCII
Overflow Protection Enabled =
c_OverflowProtectionEnabled_S2 6704 A[4]
ASCII
Scale 2 Overflow Protection Enabled =
c_OverflowMaxCapacityMG_S1 6705 A[30] FLT
Max Capacity (mg) =
c_OverflowMaxCapacityMG_S2 6706 A[30]
FLT
Scale 2 Max Capacity (mg) =
c_OverflowWarningPercentage_S1 6707 A[30] FLT
Warning Percentage =