Owner's manual

F-138 Appendix F - Variables Grouped by Fluidmove Activity
F.57 DJ Cycle Count
Table F.57-1 DJ Cycle Count - Equipment Constants
Variable Name ID
Storage
Type
Class
Related
CEID
Description
c_DJCycleCount_V1 6502
A[30]
*See
Description
EC None
Running total of DJ shots for Valve 1.
*The machine format of this variable is floating point that
has been converted to a SECS/GEM string variable to
prevent rounding and truncation errors that would occur if
uploaded as a float. To reset this value from the SC, EC
6502 should be set to the ASCII string “0”.
c_DJCycleCount_V2 6503
A[30]
*See
Description
EC None
Running total of DJ shots for valve 2.
*The machine format of this variable is floating point that
has been converted to a SECS/GEM string variable to
prevent rounding and truncation errors that would occur if
uploaded as a float. To reset this value from the SC, EC
6503 should be set to the ASCII string “0”.
F.58 Low Fluid Collection Events
Table F.58-1 Low Fluid Collection Events
Collection Event Name
CEID
Class
Description
ce_LowFluid_V1
3696
CEID
Collection event triggered when low fluid is detected on Valve 1.
ce_LowFluid_V2
3697
CEID
Collection event triggered when low fluid is detected on valve 2.
F.59 Height Sense
Table F.59-1 Height Sense Data Variables and Collection Events
Variable Name ID
Storage
Type
Class
Related
CEID
Description
HeightSenseOriginConv1
7701
F8
EC
8401
Height Sense on Conveyor 1
ce_HeightSenseOriginConv1 8401 -- CEID -- Collection event is triggered when Height Sense is changed.
HeightSenseOriginConv2
7702
F8
EC
8402
Height Sense on Conveyor 2
ce_HeightSenseOriginConv2
8402
--
CEID
--
Collection event is triggered when Height Sense is changed.