Owner's manual

Appendix F - Variables Grouped by Fluidmove Activity F-137
F.56 Prompted Setup, Flowrate and Purge Collection Events
GEM variables and collection events have been added to notify the SECS/GEM host when a scripted prompted setup file has started and completed and
when a purge or flow rate has been performed. Some existing collection events have been expanded and are now triggered whenever a purge or flowrate is
performed (previously some were only triggered in response to a remote request to purge or to perform a flowrate).
Table F.56-1 Prompted Setup, Flowrate and Purge - Collection Events
Collection Event Name CEID
Related Data
Variables
Description
ce_PromptedSetupStarted 4001 573
Scripted prompted setup has started either manually by the operator or remotely from a
SECS/GEM host.
ce_PromptedSetupCompleted 4002 573
Scripted prompted setup has finished and all tasks have been successfully completed.
ce_PromptedSetupIncomplete
4022
573
Scripted prompted setup has finished but all tasks were not successfully completed.
ce_PromptedSetupScriptLoaded 4023 573
A scripted prompted setup file has been loaded and is ready to run.
ce_PurgePass 3740 ---
A purge has successfully completed using Valve 1.
ce_PurgePass_V2 3806 ---
A purge has successfully completed using Valve 2.
ce_PurgeFail
3766
---
A purge was started but did not successfully complete using Valve 1.
ce_PurgeFail_V2 3807 ---
A purge was started but did not successfully complete using Valve 2.
ce_FlowRateCalibComplete_V1Pass 3730 ---
A flowrate has successfully completed using Valve 1.
This collection event will also occur when an operator selects OK when running flowrate
manually.
ce_FlowRateCalibComplete_V2Pass 3731 ---
A flowrate has successfully completed using Valve 2.
This collection event will also occur when an operator selects OK when running flowrate
manually.
ce_FlowRateCalibComplete_V1Fail 3784 ---
A flowrate was performed but did not successfully complete using Valve 1.
This collection event will also occur when an operator selects CANCEL when running
flowrate manually.
ce_FlowRateCalibComplete_V2Fail 3785 ---
A flowrate was performed but did not successfully complete using Valve 2.
This collection event will also occur when an operator selects CANCEL when running
flowrate manually.
Table F.56-2 Prompted Setup, Flowrate and Purge New Data Variable
Variable Name ID
Storage
Type
Related CEID Description
PromptedSetupScriptFilename 573 A[100]
4001
4002
4022
4073
Name of currently loaded prompted setup script file.