Owner's manual
Appendix F - Variables Grouped by Fluidmove Activity F-133
F.53 Setup “Offset” Data
Table F.53-1 Setup Offset – Data Variables
Variable Name ID
SECS
Type
Storage
Type
Related
CEID
Description
HSAtPurgeLidZ 528 DV
F8
FLT
3748
Reported when the height sensor measures the Z
value of the purge cup lid. The value reported is the
Z height when the sensor is tripped in user units.
HSAtScaleLidZ* 526 DV
F8
FLT
3734
Reported when the height sensor measures the Z
value of the Scale 1 cover. The value reported is the
Z height when the sensor is tripped in user units.
HSAtScale2LidZ 531 DV
F8
FLT
3801
Reported when the height sensor measures the Z
value of the scale 2 cover. The value reported is the
Z height when the sensor is tripped in user units.
HSAtTactileZ* 524 DV
F8
FLT
3732
Reported during Needle Z Offsets. The value
reported is the Z Position when the height sensor
measures the height of the tactile in user units.
NdlAtTactileZ_V1* 525 DV
F8
FLT
3733
Reported during Needle Z Offsets. The value
reported is the Z position when the needle (nozzle)
touches the tactile (2
nd
touch / slow speed) in user
units.
SubstrateCornerTL 529 DV
A[40]
FLT,FLT
3800
The top left (TL) corner location of the substrate in
user units. Reported during Needle to Camera XY
Offsets when the corners of the substrate are used to
determine the locations of the four dispense dots.
SubstrateCornerBR 530 DV
A[40]
FLT,FLT
3800
The bottom right (BR) corner location of the substrate
in user units. Reported during Needle to Camera XY
Offsets when the corners of the substrate are used to
determine the locations of the four dispense dots.
TactileCenter 532 DV
A[40]
FLT,FLT
3802
Reported during Needle Z Offsets. The value
reported is the center of the tactile in user units.