Owner's manual

Appendix F - Variables Grouped by Fluidmove Activity F-131
FlowRateCalib - Remote Command (existing command)
Use this command to run CPJ. If pressure control is not enabled, CPJ without pressure control will be executed. If pressure control is enabled, CPJ with
pressure control (DWCA) will be executed.
CPJ with Pressure Control Data Variables and Collection Events
Table F.52-4 CPJ with Pressure Control Data Variables
Data Variable Name ID
SECS
Type
Class
Related
Collection
Events
Description
DWCA_DesiredDotWeight 645 FLT DV 5046
Desired dot weight during CPJ routine
DWCA_FinalDotWeight 646 FLT DV 5047
Final dot weight when CPJ completes successfully
DWCA_PressureAtFinalDotWeight 647 FLT DV 5047
Final pressure at dot weight when CPJ completes
successfully
DWCA_DeviationMaxPC 648 FLT DV 5046
Maximum dot weight deviation (percentage)
DWCA_IntermediateDotWeight 649 FLT DV 5044
Out of tolerance dot weight measured before reiteration
DWCA_IntermediatePressure 650 FLT DV 5044
Pressure when out of tolerance dot weight failed
DWCA_StartingPressure 651 FLT DV 5046
Beginning pressure when CPJ is started
DWCA_StartingDotWeight 652 FLT DV 5046
Beginning dot weight when CPJ is started