Owner's manual
F-130 Appendix F - Variables Grouped by Fluidmove Activity
Table F.52-2 Dot Weight Pressure Setup – Data Variables (continued)
Data Variable Name ID
SECS
Type
Class
Related
Collection
Events
Description
DWCA_IntermediateDotWeight 649 FLT DV 5044
Out of tolerance dot weight measured. Tool will retry
unless retries exhausted.
DWCA_IntermediatePressure 650 FLT DV 5044
Pressure when dot weight failed. Tool will retry unless
retries exhausted.
Table F.52-3 Dot Weight Pressure Setup – Related Collection Events
Collection Event Name CEID
Related Data
Variables
Description
ce_DWCA_SetupStarted 5040
641
643
645
648
Initial collection event signaling start of DWCA setup (DJ9K Dot Weight
Pressure Setup).
ce_DWCA_MinPressureCompleted 5041
643
644
Intermediate collection event when dot weight at minimum pressure has
been completed.
ce_DWCA_MaxPressureCompleted 5042
641
642
Intermediate collection event when dot weight at maximum pressure
has been completed.
ce_DWCA_SetupCompleted 5043
641
642
643
644
645
646
647
648
Final collection event when final dot weight and pressure has been
computed and DWCA setup has completed successfully.
ce_DWCA_IntermediateValues 5044
649
650
Intermediate collection event when a fluid pressure / dot weight has
failed calibration and the routine is adjusting pressure. The tool will
retry unless retries exhausted.
ce_DWCA_SetupFailed 5045 -
Collection event if setup failed or was aborted by user or tool error.
This collection event signals that the DWCA setup routine (DJ9K Dot
Weight Pressure Setup) has completed unsuccessfully.