Owner's manual
Appendix F - Variables Grouped by Fluidmove Activity F-129
Dot Weight Pressure Setup Data Variables and Collection Events
Dot Weight Pressure Setup can be run remotely or manually from the Fluid Manager. When run remotely, setup variables such as desired dot weight and
min and max pressure are initialized directly from the currently loaded Fluid File. When run manually from the Fluid Manager, these variables reflect the
values entered by an operator in the user interface, which may or may not be the same values stored in the Fluid File.
The three “coordinate” pairs that define the calibration curve are:
DWCA_MinPressure, DWCA_DotWeightAtMinPressure
DWCA_PressureAtFinalDotWeight, DWCA_FinalDotWeight
DWCA_MaxPressure, DWCA_DotWeightAtMaxPressure
Intermediate “failed” attempts when determining a final dot weight/pressure are stored in DWCA_IntermediatePressure and
DWCA_IntermediateDotWeight.
Table F.52-2 Dot Weight Pressure Setup – Data Variables
Data Variable Name ID
SECS
Type
Class
Related
Collection
Events
Description
DWCA_MaxPressure 641 FLT DV
5040
5042
5043
Maximum pressure used when determining
calibration curve
DWCA_DotWeightAtMaxPressure 642 FLT DV
5042
5043
Dot weight measured at maximum pressure
DWCA_MinPressure 643 FLT DV
5040
5041
5043
Minimum pressure used when determining calibration
curve
DWCA_DotWeightAtMinPressure 644 FLT DV
5041
5043
Dot weight measured at minimum pressure
DWCA_DesiredDotWeight 645 FLT DV
5040
5043
Desired dot weight during setup routine
DWCA_FinalDotWeight
646
FLT
DV
5043
Final dot weight when setup completes successfully
DWCA_PressureAtFinalDotWeight 647 FLT DV 5043
Final pressure at dot weight when setup completes
successfully
DWCA_DeviationMaxPC 648 FLT DV
5040
5043
Maximum dot weight deviation (percentage)