Owner's manual
F-128 Appendix F - Variables Grouped by Fluidmove Activity
F.52 Pressure Controlled CPJ (DWCA) Variables
Control Dot Weight – Remote Command
This is the remote command for changing pressure control from ON to OFF or vice versa.
This command will alter the contents of the fluid file currently loaded.
The command will be rejected if not in remote mode or if a program is running.
When changing pressure states, the dot weight computed from the previous state will still be in effect. I.e., the pressure controlled dot weight and the non-
pressure controlled dot weight is not stored separately and will not automatically change to match the pressure setting when pressure control is turned on
or off. Therefore, when changing states, the appropriate CPJ or DWCA setup routine must be executed:
When changing from the non-pressure controlled state to the pressure controlled state, DWCA “setup” should be run using the remote command “DJ9K
DOT WEIGHT PRESSURE SETUP”. When changing from the pressure controlled state to the non-pressure controlled state, CPJ should be run using the
remote command “FLOWRATECALIB”.
DJ9K Dot Weight Pressure Setup – Remote Command
Use this command to initiate the dot weight pressure “setup” routine. To run this routine, pressure control must be enabled, a program must be running
and the tool must be in remote mode.
Table F.52-1 Dot Weight Pressure Setup – Rejection HCACK
Rejection
HCACK
Reason
0x01 Valve is not a Jet
0x02 Not in valid Fluidmove Window
0x40 Not in remote mode
0x41 Programming is running
0x45 Pressure Control is not enabled