Appendix F - Variables Grouped by Fluidmove Activity F-115
F.46 Controlled Process Heat (CpH) Air Flow Variables
The following status variables reflect the current air flow for the specified lane and station.
“-1” indicates air flow is not available. Units are specified by variable c_AirflowUnits (see below).
NOTE: These status variables are valid only if CpH is enabled (see ECID 6523 - c_CpH_Enabled).
Table F.46-1 CPH Air Flow - Status Variables
Status Variable Name ID
SECS
Type
Storage Type Description
AF_L1S1 1269 F8 FLT Current air flow for Lane 1 Station 1.
AF_L1S2 1270 F8 FLT Current air flow for Lane 1 Station 2.
AF_L1S3 1271 F8 FLT Current air flow for Lane 1 Station 3.
AF_L2S1 1272 F8 FLT Current air flow for Lane 2 Station 1.
AF_L2S2 1273 F8 FLT Current air flow for Lane 2 Station 2.
AF_L2S3 1274 F8 FLT Current air flow for Lane 2 Station 3.
AF_L1S1_Limits_Enabled 1275 A[4] ASCII
Air flow limits enabled for Lane 1 station 1.
Value will be “ON” or “OFF”.
AF_L1S1_UpperLimitOffset 1276 F8 FLT Upper limit air flow offset for Lane 1 station 1.
AF_L1S1_LowerLimitOffset 1277 F8 FLT Lower limit air flow offset for Lane 1 station 1.
AF_L1S2_Limits_Enabled 1278 A[4] ASCII
Air flow limits enabled for Lane 1 station 2.
Value will be “ON” or “OFF”.
AF_L1S2_UpperLimitOffset 1279 F8 FLT Upper limit air flow offset for Lane 1 station 2.
AF_L1S2_LowerLimitOffset 1280 F8 FLT Lower limit air flow offset for Lane 1 station 2.
AF_L1S3_Limits_Enabled 1281 A[4] ASCII
Air flow limits enabled for Lane 1 station 3.
Value will be “ON” or “OFF”.
AF_L1S3_UpperLimitOffset 1282 F8 FLT Upper limit air flow offset for Lane 1 station 3.
AF_L1S3_LowerLimitOffset 1283 F8 FLT Lower limit air flow offset for Lane 1 station 3.