Owner's manual
F-114 Appendix F - Variables Grouped by Fluidmove Activity
F.45 Auto Setup Variables
The following SECS/GEM variables pertain to “auto setup” of the Asymtek tool.
Table F.45-1 Auto Setup - Remote Command
Variable Name
ID
SECS
Type
Storage
Type
Class
Related
CEIDS
Description
HSAtTactileZ 524 FLT FLT DV 3732
Captured Z value when height sensor trips on tactile
surface during needle to height sensor offsets.
NOTE: This value is now in user units.
NdlAtTactileZ_V1 525 FLT FLT DV 3733
Captured Z value when Valve 1 needle (nozzle)
touches tactile during needle to height sensor
offsets.
NOTE: This value is now in user units.
HSAtScaleLidZ 526 FLT FLT DV 3734
Captured Z value when height sensor detects scale
lid. “ScaleNumber” vid 522 denotes which scale.
NOTE: This value is now in user units.
c_ServiceStationFidXY_1 6526 A[40] FLT,FLT EC
3638
3742
XY location of service station fiducial 1 (left pin).
c_ServiceStationFidXY_2 6527 A[40] FLT,FLT EC
3638
3742
XY location of service station fiducial 2 (right pin).
Table F.45-2 Auto Setup – Collection Events
Collection Event Name CEID
Related Data
Variables
Description
ce_HSAtTactileZ 3732 524
Collection event when height sensor Z value is captured during needle
to height sensor offsets.
Note: this CE can occur multiple times during a single offset session if
multiple reps are configured.
ce_NdlAtTactileZ_V1 3733 525
Collection event when Valve 1 needle (nozzle) Z value is captured
during needle to height sensor offsets.
Note: this CE can occur multiple times during a single offset session if
multiple reps are configured.
ce_HSAtScaleLidZ 3734 526
Collection event when height sensor Z value is captured on scale lid
during “teach scale location”. “ScaleNumber” vid denotes which scale.