Owner's manual
F-98 Appendix F - Variables Grouped by Fluidmove Activity
F.36 Control Dot Weight – Remote Command
Control Dot Weight option controls the jet valve dispense dot weight using the electronic fluid pressure control. The SECS/GEM host can turn this feature
on or off with a remote command sent to the client machine. The following tables describe the SECS/GEM remote command and collection events related
Control Dot Weight.
Table F.36-1 Control Dot Weight – Remote Command
Remote Command CEID
Related Data
Variables
Description
Remote Command String =
“ CONTROL DOT WEIGHT”
Remote control command will include the
enable value and the optional valve name
and number in the command parameters.
(SECS/GEM S2F41 format) No valve
parameter defaults to Valve 1.
Remote command to enable/disable Control Dot Weight fluid
parameter.
3798 ce_ControlDotWeightON
3799 ce_ControlDotWeightOFF
The remote command includes an argument to turn the fluid Control Dot Weight parameter on and off and an optional valve name and number to select
the valve. No valve parameter will set Valve 1 by default. (SECS/GEM S2F41 format, Remote Command with Parameters)
Usage Scenario
The SECS/GEM host sends the remote command “CONTROL DOT WEIGHT” with parameters 1 to enable and 0 to disable the feature. Confirmation
collection events are generated after the fluid file parameter is set.
Table F.36-2 Control Dot Weight – Collection Events
CEID Description
3798 ce_ControlDotWeightON
3799 ce_ControlDotWeightOFF