Owner's manual
Appendix F - Variables Grouped by Fluidmove Activity F-95
F.35 Preliminary Needle To Camera Offsets – Remote Command
Preliminary Needle to Camera XY Offsets is a script command used during machine setup to locate the Needle/Jet relative to the camera. The SECS/GEM
host can start this process with a remote command sent to the client machine. The following tables describe the SECS/GEM remote command and
variables related Preliminary Needle to Camera XY Offsets.
Table F.35-1 Preliminary Needle to Camera Offsets – Remote Command
Remote Command CEID
Related Data
Variables
Description
Remote Command String =
“ PRELIM NEEDLE TO CAMERA”
Remote control command to start Preliminary Needle To Camera
Offsets process.
3745 ce_PrelimNeedleToCameraPass
3771 ce_PrelimNeedleToCameraFail
The remote command can include the valve name and number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters)
No parameters in the command message will default to Valve 1.
Table F.35-2 Preliminary Needle to Camera Offsets – Equipment Constants
Variable Name ID
Storage
Type
SECS
Type
CEID Description
c_PrelimNeedleLocation_V1 6362 A40 EC 3745 Preliminary Needle to Camera Location Valve 1.
c_PrelimNeedleLocation_V2
Valve 2 variable is not defined in the current
GCP file.
------ A40 EC 3745 Preliminary Needle to Camera Location Valve 2.